Histological evaluation of oral implants inserted with different surgical techniques into the trabecular bone of goats
Authors:Shalabi Manal M  Wolke Johannes G C  de Ruijter Anja J E  Jansen John A
Institution:Department of Periodontology and Biomaterials, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands.
Abstract:OBJECTIVE: The aim of this study was to investigate the influence of implant surface topography and surgical technique on bone response. MATERIAL AND METHODS: For the experiment, 48 screw-designed implants were used with two different surface finishes, i.e. machined and 'blasted, etched'. The implants were inserted into the left and right medial femoral condyle of eight goats using three different surgical approaches: press-fit (implant diameter=implant bed diamete(r), undersized (implant bed diameter
Keywords:implant              in vivo model  histology  surface roughness  surgical technique