首页 | 本学科首页   官方微博 | 高级检索  
     


Isolated aorta setup for hemodynamic studies
Authors:Pieter Sipkema  Ricky D. Latham  Nicolaas Westerhof  Bernard J. Rubal  David M. Slife
Affiliation:(1) Laboratory for Physiology Free, University of Amsterdam, P. O. Box7161, Amsterdam, The Netherlands;(2) Cardiology Service Department of Medicine, Brooke Army Medical Center, Fort Sam, Houston, TX
Abstract:A setup consisting of a high-performance hydraulic pump connected to the ascending part of an isolated aorta, including all major distal branches, each loaded with calibrated artificial resistors, was developed. The system was used to study total aortic compliance of the baboon as a function of mean aortic pressure (n=5). The aorta loaded with the resistors was mounted in a custom-designed sink table, such that it was submersed in physiological saline maintained at 37°C. Mean distending pressure in the entire aortic compliance from pressure and flow waves generated by the pump. Total aortic compliance as a function of mean pressure was fitted with a logarithmic function: Ln (Compliance)=A+B * P. The value of A(±SE) was: 1.565±0.319 and B: −0.020±0.003 (P<0.001). The results were compared with previously published results (also using the same three-element Windkessel fit) obtained in three of the same animalsin vivo. Thein vivo data were A: 1.095±0.235 and B: −0.019±0.003.In vitro data had a significantly higher value of A thanin vivo (P=0.017), implying a significantly higher aortic compliancein vitro thanin vivo. Occlusion of the proximal descending aorta was performed at a low distending pressure (55 mm Hg) to determine the proximal complicance. It was found (n=4) that 46±11% (SD) of the total arterial compliance is to be attributed to the ascending and proximal descending aorta. This work was supported in part by Grant RG 86/0066 from the scientific affairs division of Nato.
Keywords:Isolated aorta  Compliance  Windkessel model
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号