首页 | 本学科首页   官方微博 | 高级检索  
检索        

全中枢照射技术新探索
引用本文:杨金磊,吴丹,卜明伟,路双臣,张贺.全中枢照射技术新探索[J].中国医学物理学杂志,2012,29(3):3354-3357,3374.
作者姓名:杨金磊  吴丹  卜明伟  路双臣  张贺
作者单位:1. 吉林省肿瘤医院放疗研究室,吉林长春,130012
2. 吉林大学物理学院,吉林长春,130012
摘    要:目的:阐述一种普遍适合于全中枢放射治疗的方法。方法:使用precise plan三维适形计划系统进行计划设计,在计划设计过程中综合利用了非共面射野衔接技术、相邻两野相切技术和正向子野添加技术,最后利用detla4三维剂量验证模体对射野衔接处进行剂量测量验证。结果:计划显示在射野衔接处没有明显的剂量冷点或者热点出现,衔接位置两侧各条等剂量线实现了无缝衔接,靶区得到了理想的剂量分布;并且在剂量验证的过程中发现,当模拟的移床精度控制在±1 mm时,detla4测量衔接处没有明显的剂量偏差,结果符合临床治疗需要。结论:与以往及常规方法相比,本文提到的这种方法适合于绝大多数全中枢放射治疗病例,并且可以在射野衔接处获得更为理想的剂量分布效果。

关 键 词:全脑全脊髓放疗  射野衔接  多等中心放射治疗

Novel Exploration of Craniospinal Radiotherapy Technique
YANG Jin-lei , WU Dan , BU Ming-wei , LU Shuang-chen , ZHANG He.Novel Exploration of Craniospinal Radiotherapy Technique[J].Chinese Journal of Medical Physics,2012,29(3):3354-3357,3374.
Authors:YANG Jin-lei  WU Dan  BU Ming-wei  LU Shuang-chen  ZHANG He
Institution:1.The Radiotherapy Research Department,Cancer Hospital of Jilin Province,Changchun Jilin 130012 China;2.Academy of Physics,Jilin University,Changchun Jilin 130012 China)
Abstract:Objective: This paper introduces a universal suitable method for craniospinal radiotherapy.Methods: The planning was completed by using the precise plan three-dimensional conformal planning system.It was designed with the comprehensive utilization of non-coplanar beam junction technique,tangential irradiation and MLC segment technique.At last,the dose measurement on beam junctions was tested by the detla4 three-dimensional dose verification phantom.Results: The planning displayed that there were no "cold spots" or"hot spots" on beam junctions.Each isodose line was realized the seamless connection on both sides of the beams junction.The ideal dose distribution was obtained in the target area.And it was found in quality assurance process that there were no obvious dose errors on beam junctions measured by detla4 when the precision of the moving couch was controlled in ?à1 mm.The Result is consistent with the need in clinical treatment.Conclusions: This method is suitable for the vast majority of craniospinal radiotherapy cases compared with some previous traditional methods.The better dose distribution can be obtained on beam junctions.
Keywords:craniospinal radiotherapy portals join multi-isocenter radiotherapy
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号