首页 | 本学科首页   官方微博 | 高级检索  
检索        


Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacement
Authors:Markl Michael  Draney Mary T  Miller D Craig  Levin Jonathan M  Williamson Eric E  Pelc Norbert J  Liang David H  Herfkens Robert J
Institution:Department of Radiology, Stanford University, CA 94304, USA.
Abstract:OBJECTIVE: To provide more complete characterization of ascending aortic blood flow, including vortex formation behind the valve cusps, in healthy subjects and patients after valve-sparing aortic root replacement (David reimplantation). METHODS: Time-resolved 3-dimensional magnetic resonance imaging velocity mapping was performed to analyze pulsatile blood flow by using encoded 3-directional vector fields in the thoracic aortas of 10 volunteers and 12 patients after David reimplantation using a cylindrical tube graft (T. David I) and two versions of neosinus recreation (T. David-V and T. David-V-S mod ). Aortic flow was evaluated by using 3-dimensional time-resolved particle traces and velocity vector fields reformatted onto 2-dimensional planes. Semiquantitative data were derived by using a blinded grading system (0-3: 0, none; 1, minimal; 2, medium; 3, prominent) to analyze the systolic vortex formation behind the cusps, as well as retrograde and helical flow in the ascending aorta. RESULTS: Systolic vortices were seen in both coronary sinuses of all volunteers (greater in the left sinus 2.5 +/- 0.5] than the right 1.8 +/- 0.8]) but in only 4 of 10 noncoronary sinuses (0.7 +/- 0.9). Comparable coronary vortices were detected in all operated patients. Vorticity was minimal in the noncoronary cusp in T. David-I repairs (0.7 +/- 0.7) but was prominent in T. David-V noncoronary graft pseudosinuses (1.5 +/- 0.6; P = .035). Retrograde flow (P = .001) and helicity (P = .028) were found in all patients but were not distinguishable from normal values in the T. David-V-S mod patients. CONCLUSIONS: Coronary cusp vorticity was preserved after David reimplantation, regardless of neosinus creation. Increased retrograde flow and helicity were more prominent in T. David-V patients. These novel magnetic resonance imaging methods can assess the clinical implications of altered aortic flow dynamics in patients undergoing various types of valve-sparing aortic root replacement.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号