Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial |
| |
Authors: | Ahmed Mohamed Abohabib Mona Mohamed Fayed Amr H. Labib |
| |
Affiliation: | 1. Faculty of Dentistry, Kafrelsheikh University, Karfelskeikh, Egypt;2. Department of Orthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt;3. Department of Pediatric Dentistry and Orthodontics, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia |
| |
Abstract: | Objective: To investigate the effect of low-intensity laser therapy on mini-implant stability using resonance frequency analysis during canine retraction with fixed appliances.Design: A split-mouth randomised clinical trial.Setting: Subjects were recruited and treated in the outpatient clinic, Department of Orthodontics, Faculty of Dentistry, Cairo University.Participants: Fifteen subjects with mean age 20.9 (±3.4) years who required extraction of maxillary first premolar teeth and mini-implant-supported canine retraction.Methods: Thirty orthodontic mini-implants were inserted bilaterally in the maxillary arches of recruited subjects following alignment and levelling. Mini-implants were immediately loaded with a force of 150?g using nickel titanium coil springs with split-mouth randomisation to a low-intensity laser-treated side and control side. The experimental sides were exposed to low-intensity laser therapy from a diode laser with a wavelength of 940?nm at (0, 7, 14, 21 days) after mini-implant placement. Mini-implant stability was measured using resonance frequency analysis at (0, 1, 2, 3, 4, 6, 8, 10 weeks) after implant placement.Results: A total sample of 28 mini-implants were investigated with 14 in each group. Clinically, both mini-implant groups had the same overall success rate of 78.5%. There were no significant differences in resonance frequency scores between low-intensity laser and control sides from baseline to week 2. However, from week 3 to 10, the low-intensity laser sides showed significantly increased mean resonance frequency values compared to control (P?>?0.05).Conclusions: Despite evidence of some significant differences in resonance frequency between mini-implants exposed to low-intensity laser light over a 10 weeks period there were no differences in mini-implant stability. Low-intensity laser light cannot be recommended as a clinically useful adjunct to promoting mini-implant stability during canine retraction. |
| |
Keywords: | Orthodontic mini-implants mini-screws low-intensity laser resonance frequency analysis |
|
|