Abstract: | Out of 989 cases with a ball-valve prosthesis, 66 have been reoperated (6.7%). 2.9% of the cases reviewed annually have thus been reoperated. The main indications for reoperation were displacement (75.5%), malfunction (10.5%) which was related to a failure of the material of the prosthesis or to the deposition of fibrinous plaques, and associated lesions (14%) which were valvular, coronary or myocardial. There were multiple complications in 36 patients. The operative mortality was 31.8% (21.7% over the last two years). On statistical analysis, the significant risk factors were a previous history of bacterial endocarditis, grouping in Class IV of the NYHA classification, enlargement of the QRS complex (0.12 s), urgency of reoperation, and prolonged extracorporeal circulation (2 hours). The rapid fall in survival time was due in part to late deaths (16 patients). By way of contrast, the clinical result was satisfactory in 71% of the survivors. Analysis of the causes of failures has lead to a search for ways of preventing the necessity for reoperation. |