Comparison of Tc-99m pyrophosphate and Tc-99m methylene diphosphonate in acute myocardial infarction: concise communication.
Authors:R J Kelly  H Chilton  B T Hackshaw  J D Ball  N E Watson  F R Kahl  F J Cowan
Abstract:This study compared Tc-99m pyrophosphate (PPi) and Tc-99m methylene diphosphonate (MDP) for myocardial infarct imaging in 24 patients with diagnosed acute myocardial infarction. The radiopharmaceuticals were administered randomly and interpreted without knowledge of the sequence used. Twenty-three patients (96%) had positive Tc-99m PPi scintigrams, but only 17 (71%) had a positive Tc-99m MDP study (P less than 0.05). In addition, a comparison of the relative intensity with each agent revealed greater intensity with Tc-99m in 21 cases, equal intensity in two cases, and less intensity in only one case (p less than 0.001). These findings support the superiority of Tc-99m PPi as the agent of choice for myocardial scintigraphy in acute infarction.