Colon explosion during argon plasma coagulation |
| |
Authors: | Manner Hendrik Plum Nicola Pech Oliver Ell Christian Enderle Markus D |
| |
Affiliation: | aCurrent affiliations: Department of Internal Medicine II (H.M., N.P., O.P., C.E.), HSK Wiesbaden, Wiesbaden, Erbe Elektromedizin GmbH (M.D.E.), Tuebingen, Germany |
| |
Abstract: | Even when APC and other high-energy driven procedures are performed in compliance with preventive measures, the risk of colon explosion cannot completely be avoided. To date, meticulous full bowel cleansing with preparation without sugar compounds that may be malabsorbed should be carried out before any APC treatment in the colon. |
| |
Keywords: | Abbreviations: APC, argon plasma coagulation LEL, lower explosion limits UEL, upper explosion limits |