Validation of fully automatic brain SPET to MR co-registration
Authors:Leighton Barnden  Richard Kwiatek  Yiu Lau  Brian Hutton  Lennart Thurfjell  Kevin Pile  Christopher Rowe
Institution:(1) Department of Nuclear Medicine, The Queen Elizabeth Hospital, 28 Woodville Road, Woodville, SA 5011, Australia, AU;(2) Department of Rheumatology, The Queen Elizabeth Hospital, Adelaide, Australia, AU;(3) Department of Applied Physics, University of Technology Sydney and Departments of Medical Physics and Nuclear Medicine and Ultrasound, Westmead Hospital, Sydney, Australia, AU;(4) Departments of Medical Physics and Nuclear Medicine and Ultrasound, Westmead Hospital, Sydney, Australia, AU;(5) Centre for Image Analysis, University of Uppsala, S-752 37 Uppsala, Sweden, SE
Abstract:Fully automatic co-registration of functional to anatomical brain images using information intrinsic to the scans has been validated in a clinical setting for positron emission tomography (PET), but not for single-photon emission tomography (SPET). In this paper we evaluate technetium-99m hexamethylpropylene amine oxime to magnetic resonance (MR) co-registration for five fully automatic methods. We attached six small fiducial markers, visible in both SPET and MR, to the skin of 13 subjects. No increase in the radius of SPET acquisition was necessary. Distortion of the fiducial marker distribution observed in the SPET and MR studies was characterised by a measure independent of registration and three subjects were excluded on the basis of excessive distortion. The location of each fiducial marker was determined in each modality to sub-pixel precision and the inter-modality distance was averaged over all markers to give a fiducial registration error (FRE). The component of FRE excluding the variability inherent in the validation method was estimated by computing the error transformation between the arrays of MR marker locations and registered SPET marker locations. When applied to the fiducial marker locations this yielded the surface registration error (SRE), and when applied to a representative set of locations within the brain it yielded the intrinsic registration error (IRE). For the best method, mean IRE was 1.2 mm, SRE 1.5 mm and FRE 2.4 mm (with corresponding maxima of 3.3, 4.3 and 5.0 mm). All methods yielded a mean IRE <3 mm. The accuracy of the most accurate fully automatic SPET to MR co-registration was comparable with that published for PET to MR. With high standards of calibration and instrumentation, intra-subject cerebral SPET to MR registration accuracy of <2 mm is attainable. Received 29 May and in revised form 6 October 1999
Keywords:: Image registration –  Validation –  Multi-modality images –  Single-photon emission tomography –  Magnetic resonance
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号