首页 | 本学科首页   官方微博 | 高级检索  
检索        


Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures: a biomechanical study
Authors:Müller L P  Klitscher D  Rudig L  Mehler D  Rommens P M  Prommersberger K J
Institution:Department of Trauma Surgery, University Hospital of the Johannes Gutenberg-University of Mainz, Germany.
Abstract:The purpose of the study was to compare the biomechanical properties of five different palmar fixation plate designs in a distal radius osteotomy cadaver model. A 1cm metaphyseal osteotomy gap was made to simulate a corrective osteotomy and the osteotomy plated. Axial load was applied to the distal end of each construct by a material testing machine under control of a motion analysis video system. The specimens were arranged into five implant groups of eight specimens each. No test group developed deformity and movement of the fracture gap greater than 2mm with a load of 100N. Increasing the load to 250N revealed statistically significant differences in stiffness and failure load between the different plates. Axial failure strength and stiffness were greater for the radial correction plates than for the other implants. The former may provide enough stability for corrective osteotomy of dorsally angulated distal radial malunions, even when the osteotomy gap is only filled with cancellous bone graft instead of cortical bone graft.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号