首页 | 本学科首页   官方微博 | 高级检索  
     


In-vivo postoperative motion analysis of metal and ceramic bipolar hip hemiarthroplasty
Authors:Toru Yoshioka  Nobukazu Okimoto  Yoshifumi Fuse  Makoto Kawasaki  Toshiharu Mori  Akinori Sakai  Tokifumi Majima
Affiliation:1. Department of Orthopaedic Surgery, Shimura Hospital, 3-13 Funairimachi, Naka-ku, Hiroshima-shi, Hiroshima, 731-0841, Japan;2. Okimoto Clinic, 185-4 Yutakamachi Kubi, Kure-shi, Hiroshima, 734-0304, Japan;3. Department of Orthopaedic Surgery, Sakamidorii Hospital, 6-28-1 Midorii, Asaminami-ku, Hiroshima-shi, Hiroshima, 731-0103, Japan;4. Department of Orthopaedic Surgery, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu-shi, Fukuoka, 807-0804, Japan;5. Department of Orthopaedic Surgery, Shinkokura Hospital, 1-3-1 Kaneda, Kokurakita-ku, Kitakyushu-shi, Fukuoka, 803-8505, Japan;6. Department of Orthopaedic Surgery, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-ku, Tokyo, 113-8602, Japan
Abstract:

Background

We hypothesized that ceramic bipolar shows less impingement between stem neck and outer head compared to metal bipolar, because of its low coefficient of friction with the acetabulum cartilage. In this paper, a three dimensional (3D) postoperative motion analysis has been used to assess the different motion characteristics of metal and ceramic bipolar hip hemiarthroplasty systems.

Methods

This study was conducted on 40 patients divided in two matched cohorts: 20 patients with metal bipolar and 20 patients with the ceramic bipolar. We obtained motion pictures from standing position to maximum abduction in flexion by fluoroscopy then analyzed by 2D-3D image matching method. The motion range of the “Outer head angle”, “Stem neck angle” and the “Stem neck and outer head angle” was compared between the metal bipolar group and the ceramic bipolar group.

Results

The metal bipolar group's inner head's range of movement was greater than the ceramic bipolar group. Impingement between stem neck and outer head occurred in 30% of metal group patients. There were no impingement cases for the ceramic bipolar group.

Conclusions

The ceramic bipolar shows less impingement between stem neck and outer head compared to the metal bipolar. Ceramic bipolar may reduce the typical bipolar related complication and exert less effect on the acetabular cartilage due to less surface coefficient of friction.
Keywords:Corresponding author. Fax: +81 82 294 5152.
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号