首页 | 本学科首页   官方微博 | 高级检索  
     

可溶性粘附分子与冠状动脉支架植入后心脏事件的关系
引用本文:杨立森,石学宁,贾绍斌,沙勇,刘靖,方永鹏,林媛豪,潘月英,陈树兰. 可溶性粘附分子与冠状动脉支架植入后心脏事件的关系[J]. 心血管康复医学杂志, 2003, 12(4): 297-299
作者姓名:杨立森  石学宁  贾绍斌  沙勇  刘靖  方永鹏  林媛豪  潘月英  陈树兰
作者单位:宁夏医学院附属医院,宁夏,银川市,750004
摘    要:目的:检测冠心病患者冠状动脉支架植入前的可溶性细胞粘附分子水平,探讨其与以后以发生心脏事件的关系。方法:对2000年4月~2002年3月在我院接受冠状动脉支架植入的107例患者,以ELISA法检测支架植入前基础血浆可溶性粘附分子水平,并进行随访。结果:20例患者失访,随访率81.3%,随访时间3~24(平均17.4)月。随访期间心绞痛症状复发13例(14.9%),非致命性心梗2例(2.3%),猝死1(1.1%)。发生心脏事件组基础可溶性细胞间粘附分子-1(sICAM-1)水平较无心脏事件组升高(P<0.01),而可溶性血管细胞粘附分子-1(sVCAM-1)、可溶性E选择素(sE-selectin)水平在两组间无显著性差异(P>0.05)。以Kaplan-Meier法计算无心脏事件生存率,slCAM-1≥276ng/ml组2年无心脏事件生存率为67.8%,而sICAM-1<276ng/ml组为88.4%,两组间有显著性差异(P<0.01)。结论:冠状动脉支架植入前基础血浆sICAM-1水平升高的患者术后无心脏事件生存率低,sICAM-1可作为冠状动脉支架植入后心脏事件发生的预测指标。

关 键 词:冠状动脉支架植入术 心脏病 冠心病 检测 可溶性细胞粘附分子
文章编号:1008-0074(2003)04-0297-03
修稿时间:2003-05-27

Relationship between baseline plasma concentration of soluble cell adhesion molecules and subsequent cardiac events after coronary stent
'YANG Li-sen,SHI Xue-ning,JIA Shao-bin,et al.. Relationship between baseline plasma concentration of soluble cell adhesion molecules and subsequent cardiac events after coronary stent[J]. Chinese Journal of Cardiovascular Rehabilitation Medicine, 2003, 12(4): 297-299
Authors:'YANG Li-sen  SHI Xue-ning  JIA Shao-bin  et al.
Affiliation:'YANG Li-sen,SHI Xue-ning,JIA Shao-bin,et al. Author's address: Department of High-rank wards,Hospital Affiliated to Ningxia Medical College,Yinchuan,Ningxia,750004
Abstract:Objective: To evaluate whether soluble cell adhesion molecules (sCAM) are markers for subsequent cardiac events after coronary stent. Methods: Baseline plasma level of sCAM were measured from 107 patients with coronary heart disease. All patients underwent stent implantation and followed up. The follow-up period was 3-24 months and the follow-up rate was 81. 3%. All cardiac events were recorded. Results: During follow-up period, 13 cases had recurrent angina, 3 cases had non-fatal acute myocardial infarction and 1 patient suffered sudden death. Baseline concentration of soluble intercelluar adhesion molecule-1 (sICAM-1) in cardiac events group was higher than that in no-cardiac events group (P<0. 01) .The cardiac event-free survival rate calculated by Kaplan-Meier method in sICAM-1 3i276ng/ml group was 67.8% in 2 years while that in sICAM-K276ng/ml group was 88.14% (P< 0. 01). Conclusion; Patients with higher baseline level of sICAM-1 may have lower cardiac event-free survival rate after coronary stent implantation and baseline level of sICAM-1 may have prognostic value.
Keywords:Coronary heart disease  Stent  Prognosis! Soluble intercelluar adhesion molecule-1
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏