Determination of surface dose and the effect of bolus to surface dose in electron beams. |
| |
Authors: | Basri Günhan G?nül Kemikler Ayse Koca |
| |
Affiliation: | Istanbul University, Cerrahpa?a Medical Faculty Department of Radiation Oncology, Istanbul, Turkey. bagun@istanbul.edu.tr |
| |
Abstract: | When treating tumors from surface to a certain depth (<5 cm), electron beams are preferred in radiotherapy. To increase the surface doses of lower electron beams, tissue-equivalent bolus materials are often used. We observed that the surface doses increased with increasing field sizes and electron energies. At the same time, we also observed that all electron parameters were shifted toward the skin as much as the thickness of the bolus used. The effect of bolus to the surface doses was more significant at low electron energies than at higher electron energies. Rando phantom measurements at 6-, 7.5-, and 9-MeV were slightly lower than the solid phantom measurements, which could only be explained by the inverse square law effect and the Rando phantom contour irregularity. |
| |
Keywords: | |
|
|