超声造影分期诊断大动脉炎
引用本文:王超,杜国庆,田家玮,姜双全. 超声造影分期诊断大动脉炎[J]. 中国医学影像技术, 2013, 29(5): 748-751
作者姓名:王超  杜国庆  田家玮  姜双全
作者单位:哈尔滨医科大学附属第二医院超声医学科, 黑龙江 哈尔滨 150086;哈尔滨医科大学附属第二医院超声医学科, 黑龙江 哈尔滨 150086;哈尔滨医科大学附属第二医院超声医学科, 黑龙江 哈尔滨 150086;哈尔滨医科大学附属第二医院超声医学科, 黑龙江 哈尔滨 150086
基金项目:教育部高等学校博士学科点专项科研基金(20092307110017、20102307120012);黑龙江省自然科学基金(D201078);黑龙江省政府博士后资助基金(LRB09-361);黑龙江省教育厅科学技术研究面上项目(11551286)。
摘    要:目的 探讨CEUS分期诊断大动脉炎的应用价值。 方法 将15例大动脉炎患者按照临床标准分为活动期组和非活动期组,以二维超声和CEUS分别测量颈总动脉外径(D1、D2)和内膜厚度(d1、d2);用QLab软件对增厚内膜滋养动脉的造影剂信号行伽马回归曲线拟合,记录平均回声强度(EM)、峰值强度(DPI)、曲线下面积(AUC)、强度值(A)及抵消背景组织后强度值(C),比较两组差异。分别对CEUS所获D2和d2与EM、DPI、A及C进行相关性分析。 结果 活动期组颈总动脉外径和内膜厚度均大于非活动期组(P<0.05),其EM、DPI、A及C均高于非活动期组(P均<0.05);EM与D2、DPI与d2均呈正相关(r=0.871、0.508,P均<0.05)。结论 CEUS对临床分期诊断大动脉炎有较高参考价值。

关 键 词:大动脉炎  分期  造影剂  超声检查
收稿时间:2012-11-20
修稿时间:2013-01-11

Contrast-enhanced ultrasound in classification of Takayasu ateritis
WANG Chao,DU Guo-qing,TIAN Jia-wei and JIANG Shuang-quan. Contrast-enhanced ultrasound in classification of Takayasu ateritis[J]. Chinese Journal of Medical Imaging Technology, 2013, 29(5): 748-751
Authors:WANG Chao  DU Guo-qing  TIAN Jia-wei  JIANG Shuang-quan
Affiliation:Department of Ultrasound, the Second Affiliated Hospital of Harbin Medical University, Harbin 150086, China;Department of Ultrasound, the Second Affiliated Hospital of Harbin Medical University, Harbin 150086, China;Department of Ultrasound, the Second Affiliated Hospital of Harbin Medical University, Harbin 150086, China;Department of Ultrasound, the Second Affiliated Hospital of Harbin Medical University, Harbin 150086, China
Abstract:Objective To explore the diagnostic value of CEUS for the classification of Takayasu arteritis (TA). Methods CEUS characteristics were retrospectively analyzed in 15 patients with TA. The patients were divided into active group and inactive group according to clinical findings. Vessel diameter (D1, D2) and vascular wall thickness (d1, d2) were measured with the two-dimensional ultrasound and CEUS, respectively. The ROI in the dynamic images was chosen to carry out Gamma-Variate curve fitting through QLab software and made a quantitative analysis. The parameters, including echo mean (EM), derived peak intensity (DPI), area under curve (AUC), intensity values (A) and intensity values after offset background organization (C) were measured with QLab. Differences of the parameters were evaluated between the two groups. The correlation between D2, d2 and EM, DPI, A, C was analyzed when CEUS was performed. Results The diameter of common carotid artery and the thickness of endometrium in activity group were greater than those of the inactivity group (both P<0.05). EM, DPI, A and C in active group increased compared with in inactive group (all P<0.05). EM and D2, DPI and d2 had positive correlation (r=0.871, 0.508, both P<0.05). Conclusion CEUS has high reference value to the clinical staging of TA.
Keywords:Takayasu ateritis  Classification  Contrast media  Ultrasonography