首页 | 本学科首页   官方微博 | 高级检索  
     

SMILE术后角膜前表面非球面性与角膜高阶像差的关系
引用本文:苏小连,王雁. SMILE术后角膜前表面非球面性与角膜高阶像差的关系[J]. 眼视光学杂志, 2014, 0(7): 416-420
作者姓名:苏小连  王雁
作者单位:天津医科大学眼科临床学院天津市眼科医院天津市眼科学与视觉科学重点实验室天津市眼科研究所,300070
基金项目:基金项目:周家自然科学基金(81170873);天津市卫生局攻关项目(10KG109)
摘    要:目的探讨SMILE术后角膜前表面非球面性与角膜高阶像差变化特点及其相关性。方法前瞻性研究。随机选取自愿行SMILE手术的屈光不正患者41例,均选右眼为研究眼,于手术前及手术后3个月分别测量患者角膜前表面6、7、8、9mm直径范同的非球面系数Q值,并测量角膜总高阶像差(HOA)、球差(Z4^0)、次级球差(Z6^0)、垂直彗差(Z3^-1)、水平彗差(Z3^1)、水平三叶草(Z3^-3)、倾斜三叶卓(Z3^3)等高阶像差。采用配对t检验和Pearson相关进行数据分析。结果SMILE手术后角膜前表面6、7、8、9mm直径范围Q值均Fh负值转变为正值(t=-23.558、-26.661、-28.366、-28.788,P〈0.01)。角膜HOA、Z4^0、Z6^0、Z3^-1、Z3^1数值均增大(t=-11.815、-11.813、-16.209、6.470、4.835,P〈0.01),而Z3^-3、Z3^3与术前比较差异无统计学意义(t=0.278、-1.064,P〉0.05)。术前角膜HOA、Z4^0、Z3^-1与Q值有-定的相关性(P〈0.05),SMILE手术前后角膜HOA、Z4^0差值与角膜前表面各直径范同Q值差值均呈正相关关系(HOA:r=0.554、0.480、0.416、0.352,P〈0.05;Z40:r=0.671、0.577、0.495、0.395,P〈0.05):Z3^-1差值与6、7mm直径范同Q值差值呈正相关(r=0.377、0.342,P〈0.05);Z3^-1差值与6、7、8mm直径范同Q值差倩呈止相关(r=0.436、0.385、0.316,P〈0.05);Z6^0、Z3^-3、Z3^3差值与各直径范同Q值差值均无相关性。透镜直径与SMILE手术前后Q值差值无相关性;与角膜HOA、Z4^0差值呈负相关(r=-0.315.-0.393,P〈0.05);与角膜Z6^0、Z3^-1、Z3^-1、Z3^-1、Z3^3差值均无相关性(P〉O.05)。结论SMILE手术后角膜前表面O值由负值转变为止佰;角膜高阶像差增大;透镜直径越大,角膜HOA、Z4^0变化越小。角膜前表面Q值与角膜HOA、Z4^0、Z3^-1、Z3^1变化量均有正相关关系,其中与Z4^0相关程度最强?

关 键 词:飞秒激光  飞秒激光小切口基质透镜取出术  视觉质量  Q值  高阶像差

The correlation between corneal asphericity and higher order aberrations after SMILE surgery
Su Xiaolian,Wang Yan. The correlation between corneal asphericity and higher order aberrations after SMILE surgery[J]. Chinese Journal of Optometry & Ophthalmology, 2014, 0(7): 416-420
Authors:Su Xiaolian  Wang Yan
Affiliation:( Clinical College of Ophthalmology Tianjin Medical University, Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin 300070, China)
Abstract:Objective To evaluate the characteristics of anterior corneal asphericity and higher order aberrations after SMILE surgery, and to analyze the correlation between them. Methods In this prospective study, 41 subjects who underwent SMILE surgery were enrolled with right eyes selected for the study. The aspherieity coefficient Q-value at diameters of 6, 7, 8 and 9 mm and total higher order aberrations (HOA), spherical aben'ations (Z4^0), secondary spherical aberrations 1 (Z6^0), vertieal coma (Z3^-1), horizontal coma (Z3^1), y-trefoil (Z3^-3) and x-trefoil (Z3^3) of the cornea were measured before surgery and 3 months following the surgery. A paired-samples t test and Pearson correlation were used for analysis. Results All Q-values increased from negative to positive after SMILE surgery and the differences were statistically significant (t=-23.558, -26.661, -28.366, -28.788, P〈0.01). Corneal HOA, Z4^0, Z6^0, Z3^-1 and Z3^1 increased and the differences were statistically significant as well (t=-11.815, -11.813, -16.209, 6.470, 4.835, P〈0.01). However, the change in Z3^-3 or Z3^3 was not signifieant (t=0.278, -1.064, P〉0.05). Among corneal higher order aberrations, a linearcorrelation was found between the Q-value and corneal HOA, Z4^0 and Z3^-1 before surgery (P〈0.05). The change in corneal HOA and Z4^0 had a positive linear correlation with the Q-value at each diameter (HOA: r=0.554, 0.480, 0.416, 0.352, P〈0.05; Z4^0: r=0.671, 0.577, 0.495, 0.395, P〈0.05). The difference in Z3^-1 had a positive linear correlation with the Q-values at diameters 6 and 7 mm (r=0.377, 0.342, P〈0.05). The difference in Z31 had a positive linear correlation with the Q-values at diameters 6, 7 and 8 mm (r=0.436, 0.385, 0.316, P〈0.05). No linear correlation was found between the changes in the Q-values at each diameter and those of Z3^-3, Z3^3 or Z6^0 (P〉0.05). There was not a linear correlation between the change in the Q-values and lens diameter (P〉0
Keywords:Femtosecond laser  Small incision lenticule extraction  Visual quality  Q-value  Higher order aberration
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号