首页 | 本学科首页   官方微博 | 高级检索  
     


Detecting Incipient Vasovagal Syncope: Intraventricular Acceleration
Authors:MICHELE BRIGNOLE,CARLO MENOZZI,,GIORGIO CORBUCCI,&dagger  ,BRUNO GARBEROGLIO,&dagger  ,GIANNI PLICCHI&Dagger  
Affiliation:Section of Arrhythmology, Ospedali Riuniti, Lavagna;Section of Arrhythmology, Ospedale S Maria Nuova, Reggio Emilia;Sorin Biomedica, Saluggia;Biomedical Technology Department, University of Bologna, Bologna, Italy
Abstract:The peak endocardial acceleration (PEA) caused by ventricular isometric contraction can be measured with an implantable microaccelerometer located inside the tip of a normal unipolar pacing lead. It has been shown that PEA correlates with myocardiai contractility and the maximum rate of rise of ventricular pressure (peak dP/dt) of the left ventricle. A PEA measuring system was temporarily inserted into the apex of the right ventricle in seven patients affected by syncope of uncertain origin. Each patient subsequently underwent 60 tilt testing with three different protocols: without pharmacological challenge (baseline); potentiated with sublingual trinitroglycerin (at a dose of 0.3 mg); and with isoproterenol infusion (at a dose of 3 μg/min). Each phase lasted 20 minutes. Syncope was induced in 1 patient during the baseline phase, in 3 patients during the trinitrin phase, and in 4 patients during the isoproterenol phase. Six patients had a negative response during the baseline phase and served as a control group. From the beginning of upright posture to the time of maximum heart rate, PEA increased by about the same amount in both positive and negative patients, but absolute values were from two- to three fold higher with isoproterenol (from 1.2 ± 0.5 G to 1.6 ± 0.8 G, from 0.8 ± 0.2 G to 1.2 ± 0.4 G, and from 2.8 ± 1.8 G to 3.6 ± 1.8 G, respectively, for negative, positive baseline or trinitrin, and positive isoproterenol tests). At the time of syncope, PEA values fell to baseline values. PEA changes were inversely correlated with blood pressure changes and directly correlated with heart rate changes. Thus, tilt induced syncope occurred both at low and high levels of left ventricular contractility. Whether spontaneous syncopes occur at low or high PEA behavior remains to be established. Since heart rate correlates well with changes in PEA and is far easier to measure, it is unlikely that a PEA measurement system or, in general, a contractility-based system, might become an ideal sensing parameter for the introduction of devices to combat vasovagal syncope.
Keywords:peak endocardial acceleration    vasovagal syncope    tilt testing
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号