首页 | 本学科首页   官方微博 | 高级检索  
     


Open-source,vendor-independent,automated multi-beat tissue Doppler echocardiography analysis
Authors:Niti M. Dhutia  Massoud Zolgharni  Michael Mielewczik  Madalina Negoita  Stefania Sacchi  Karikaran Manoharan  Darrel P. Francis  Graham D. Cole
Affiliation:1.National Heart and Lung Institute,Imperial College London,London,UK
Abstract:Current guidelines for measuring cardiac function by tissue Doppler recommend using multiple beats, but this has a time cost for human operators. We present an open-source, vendor-independent, drag-and-drop software capable of automating the measurement process. A database of ~8000 tissue Doppler beats (48 patients) from the septal and lateral annuli were analyzed by three expert echocardiographers. We developed an intensity- and gradient-based automated algorithm to measure tissue Doppler velocities. We tested its performance against manual measurements from the expert human operators. Our algorithm showed strong agreement with expert human operators. Performance was indistinguishable from a human operator: for algorithm, mean difference and SDD from the mean of human operators’ estimates 0.48?±?1.12 cm/s (R2?=?0.82); for the humans individually this was 0.43?±?1.11 cm/s (R2?=?0.84), ?0.88?±?1.12 cm/s (R2?=?0.84) and 0.41?±?1.30 cm/s (R2?=?0.78). Agreement between operators and the automated algorithm was preserved when measuring at either the edge or middle of the trace. The algorithm was 10-fold quicker than manual measurements (p?
Keywords:
本文献已被 SpringerLink 等数据库收录!