首页 | 本学科首页   官方微博 | 高级检索  
检索        

256层螺旋CT心电门控成像在诊断先天性心脏病中的临床应用
引用本文:田新华,刘建华,弓婷婷,耿丽莉,孙勇.256层螺旋CT心电门控成像在诊断先天性心脏病中的临床应用[J].吉林大学学报(医学版),2011,0(5):931-934.
作者姓名:田新华  刘建华  弓婷婷  耿丽莉  孙勇
作者单位:吉林大学第二医院放射线科,吉林长春,130041;吉林省吉林市第二中心医院放射线科,吉林吉林,132001;昆明医学院附属二院放射线科,云南昆明,650101
基金项目:国家自然科学基金课题,云南省科技厅科研基金课题
摘    要:目的:探讨256层螺旋CT心电门控成像在诊断先天性心脏病中的临床应用,阐明前瞻性心电门控成像与回顾性心电门控成像的图像质量与射线剂量的关系。方法:对60例怀疑先天性心脏病的患者进行心脏CT造影成像,将60例患者分为2组:前瞻性心电门控成像组和回顾性心电门控成像组,每组30例。然后对2组图像的血管强化程度、阶梯伪影、图像...

关 键 词:体层摄影术  辐射剂量  先天性心脏病
收稿时间:2011-05-08

Clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease
TIAN Xin-hua,LIU Jian-hua,GONG Ting-ting,GENG Li-li,SUN Yong.Clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease[J].Journal of Jilin University: Med Ed,2011,0(5):931-934.
Authors:TIAN Xin-hua  LIU Jian-hua  GONG Ting-ting  GENG Li-li  SUN Yong
Institution:1.Department of Radiology,Second Hospital,Jilin University,Changchun 130041,China;2.Department of Radiology,Second Central Hospital,Jilin 132001,China;3.Department of Radiology,Affiliated Hospital,Kunming Medical College,Kunming 650101,China
Abstract:Objective To investigate the clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease,and to evaluate the relationship of the image quality and radiation dose between prospective ECG-gated and retrospective ECG-gated cardiac CT angiography(CTA).Methods Sixty patients who doubt congenital heart disease underwent cardiac CTA,and they were randomly divided into two groups.Thirty patients in group A underwent prospective ECG-gated cardiac CTA,and thirty patients in group B underwent retrospective ECG-gated cardiac CTA.Then the homogeneous enhancement of vascular structures,stair-step artifact,overall image quality and radiation dose were evaluated.Results The homogeneous enhancement of vascular structures were 2.8±0.3 and 2.7±0.6,respectively,in two groups;and there was no statistical significance(P>0.05).The stair-step artifact were 3.0±0.9 and 3.1±0.9,respectively,in two groups;and there was also no statistical significance(P>0.05).The overall image quality were 3.0±0.8 and 3.1±0.9,respectively,in two groups;and there was statistical significance(P>0.05).However,the effective dose were(5.24±0.52) mSv and(16.68±1.49) mSv,respectively,in two groups;and there was statistical significance(P<0.001).Conclusion Compared with retrospective ECG-gated cardiac CTA,prospective ECG-gated cardiac CTA can reduce radiation dose about 68.6%,while maintaining the image quality which could be made diagnosis.
Keywords:tomography  radiation dose  congenital heart disease
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《吉林大学学报(医学版)》浏览原始摘要信息
点击此处可从《吉林大学学报(医学版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号