Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators |
| |
Authors: | Janssen Larry Luinenburg Michael D Mullins Haskell E Danisch Susan G Nelson Thomas J |
| |
Affiliation: | 3M Occupational Health and Environmental Safety Division, Building 0235-02-E-91, St. Paul, MN 55144-1000, USA. lljanssen@mmm.com |
| |
Abstract: | A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal leakage. The developers have used the clamp to assess respirator performance. This study evaluated the clamp's ability to measure filter penetration and determine fit factors. In Phase 1, subjects were quantitatively fit-tested with elastomeric half-facepiece respirators using both generated and ambient aerosols. QNFT were done with each aerosol with both P100 and N95 filters without disturbing the facepiece. In Phase 2 of the study elastomeric half facepieces were sealed to subjects' faces to eliminate faceseal leakage. Ambient aerosol QNFT were performed with P100 and N95 filters without disturbing the facepiece. In both phases the clamp was used to measure N95 filter penetration, which was then subtracted from total penetration for the N95 QNFT. It was hypothesized that N95 fit factors corrected for filter penetration would equal the P100 fit factors. Mean corrected N95 fit factors were significantly different from the P100 fit factors in each phase of the study. In addition, there was essentially no correlation between corrected N95 fit factors and P100 fit factors. It was concluded that the clamp method should not be used to fit-test N95 filtering facepieces or otherwise assess respirator performance. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|