首页 | 本学科首页   官方微博 | 高级检索  
     


137Cs measurement uncertainties and detection limits for airborne gamma spectrometry (AGS) data analysed using a spectral windows method.
Authors:A J Cresswell  D C W Sanderson  D C White
Affiliation:Scottish Universities Environmental Research, Rankine Avenue, Scottish Enterprise Technology Park, East Kilbride, Glasgow G75 0QF, UK. a.cresswell@suerc.gla.ac.uk
Abstract:The uncertainties associated with airborne gamma spectrometry (AGS) measurements analysed using a spectral windows method, and associated detection limits, have been investigated. For individual short measurements over buried 137Cs activity detection limits of 10 kBq m(-2) are achieved. These detection limits are reduced for superficial activity and longer integration times. For superficial activity, detection limits below 1 kBq m(-2) are achievable. A comparison is made with the detection limits for other data processing methods.
Keywords:
本文献已被 ScienceDirect 等数据库收录!