Results with the Heartstring anastomotic device in patients with diseased ascending aorta
Authors:Biancari Fausto  Mosorin Martti  Lahtinen Jarmo  Heikkinen Jouni  Rasinaho Elsi  Anttila Vesa  Lepojärvi Martti  Juvonen Tatu
Affiliation:Division of Cardio-Thoracic and Vascular Surgery, Department of Surgery, Oulu University Hospital, Oulu, Finland. faustobiancari@yahoo.it
Abstract:BACKGROUND: Avoidance of manipulation of diseased ascending aorta has been shown to be associated with a reduced risk of postoperative stroke after off-pump coronary artery bypass surgery (OPCAB). The use of the Heartstring device (Guidant, Indianapolis, USA) to accomplish a proximal aortic anastomosis without aortic clamping has been suggested in such patients. PATIENTS AND METHODS: From April 2004 to December 2005, proximal aortic anastomoses have been accomplished employing the Heartstring device in 19 patients with calcified ascending aorta who underwent OPCAB. The diagnosis of diseased ascending aorta was made intraoperatively by epiaortic ultrasound scanning. RESULTS: Eighteen vein grafts and three radial artery grafts have been successfully anastomosed to the ascending aorta by employing the Heartstring device. Breaking of eight seals occurred during insertion. One patient (5.2%) had stroke two days after urgent OPCAB. CONCLUSION: The use of the Heartstring anastomotic device should be considered in high-risk patients with diseased ascending aorta requiring a prompt myocardial revascularization, whenever there is a place to safely insert this device into the ascending aorta.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号