PET-CT诊断项目工作人员受照剂量及相关场所辐射水平测量与分析
引用本文:刘伟,何星.PET-CT诊断项目工作人员受照剂量及相关场所辐射水平测量与分析[J].中国辐射卫生,2019,28(3):278-281.
作者姓名:刘伟  何星
作者单位:江西同欣检测技术有限公司, 江西 南昌 330052
摘    要:目的 了解PET-CT诊断项目工作人员的受照剂量及相关场所的辐射水平,为降低工作人员受照剂量、完善PET-CT诊断项目放射防护措施提供科学依据。方法 依据国家相关标准,对PET-CT工作场所的周围剂量当量率、表面污染水平和人员受照剂量进行测量;根据相关检测结果与最大工作负荷对手部和眼部剂量进行估算。结果 三家医院PET-CT工作场所辐射水平(0.12~6.05 μSv/h)、β表面污染水平(本底~27.3 Bq/cm2)以及工作人员附加最大年有效剂量(1.58 mSv/a),符合国家标准规定的限值要求,其中一家医院的分装、注射护士手部最大年当量剂量(154 mSv/a)超出管理目标值(125 mSv/a)。结论 医院应建立针对性的防护措施,提高工作人员的辐射防护意识,降低工作人员所受附加剂量。

关 键 词:PET-CT诊断项目  受照剂量  放射防护  周围剂量当量率  表面污染  
收稿时间:2019-03-21

Measurement and analysis of radiation dose for staff and radiation level in related places in PET-CT diagnostic project
LIU Wei,HE Xing.Measurement and analysis of radiation dose for staff and radiation level in related places in PET-CT diagnostic project[J].Chinese Journal of Radiological Health,2019,28(3):278-281.
Authors:LIU Wei  HE Xing
Institution:Jiangxi Topthink Testing Technology Co., Ltd., Nanchang 330052 China
Abstract:Objective To understand the radiation dose of staff in PET-CT diagnostic project and the radiation level in relevant places, and to provide scientific basis for reducing the radiation dose of staff and improving the radiation protection measures of PET-CT diagnostic project. Methods Measure the ambient dose equivalent rate around the workplace, the level of surface contamination and the exposure dose to workers in PET-CT workplaces according to relevant national standards, and estimate the hand and eye doses according to the relevant test results and the maximum workload. Results The radiation level (0.12~6.05 mSv/h) and beta surface contamination level (background~27.3 Bq/cm2) in PET-CT workplaces and the maximum annual effective dose (1.58 mSv/a) of staff in three hospitals meet the national standard limits, and the maximum annual equivalent dose (154 mSv/a) of the hand of the partitioned and injected nurses exceeds the management target value (125 mSv/a). Conclusion Hospitals should establish specific protective measures to raise staff's awareness of radiation protection and reduce additional doses to staff.
Keywords:PET-CT Diagnostic Project  Exposure Dose  Radiation Protection  Ambient Dose Equivalent Rate  Surface Contamination  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国辐射卫生》浏览原始摘要信息
点击此处可从《中国辐射卫生》下载免费的PDF全文