首页 | 本学科首页   官方微博 | 高级检索  
     


KNOTTED URETERAL STENT: A MINIMALLY INVASIVE TECHNIQUE FOR REMOVAL
Authors:D. DUANE BALDWIN  G. JEREMY JURIANSZ  STEVEN STEWART  ROGER HADLEY
Affiliation:

aFrom the Division of Urology, Loma Linda University Medical Center, Loma Linda, California

Abstract:

Purpose

We describe a useful technique for untying a knotted ureteral catheter.

Materials and Methods

An Amplatz super stiff guide wire was advanced through the lumen of the stent and with uniform force the knot was untied.

Results

The knot was untied and the stent was removed. A nephrostomy tube or other more invasive techniques for removal were avoided.

Conclusions

An Amplatz super stiff guide wire passed retrograde via the ureteral stent lumen should be considered as a valid alternative to percutaneous removal of a knotted ureteral stent.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号