Measurement of brain natriuretic peptide in plasma samples and cardiac tissue extracts by means of an immunoradiometric assay method |
| |
Authors: | Del Ry S Clerico A Giannessi D Andreassi M G Caprioli R Iascone M R Ferrazzi P Biagini A |
| |
Affiliation: | Department of Cardiovascular Surgery, CNR Institute of Clinical Physiology, University of Pisa, Italy. |
| |
Abstract: | We evaluated the analytical characteristics and clinical usefulness of a commercial immunoradiometric assay (IRMA) kit for brain natriuretic peptide (BNP). Mean (+/-SD) plasma BNP concentrations measured in 129 normal subjects were 2.9+/-2.7 pmol/l (median 2.2 pmol/l; range 0.1-12.4 pmol/l). The mean (+/- SD) value observed in healthy men (2.1 +/- 2.0 pmol/l, n = 49) was significantly (p=0.0009) different to that found in women (3.4 +/- 2.9 pmol/l, n=80). A positive relationship (R=0.214, p=0.0174) was found between BNP values and age. In 65 patients with cardiac diseases, BNP levels increased with the progression of clinical severity of disease; patients with more severe disease [NYHA functional class III-IV, mean (+/- SD) BNP +/- 254 +/- 408 pmol/l, n=22] showed significantly (p<0.0001) increased values compared to patients with mild symptoms of disease (NYHA functional class I-II, mean (+/- SD) BNP=19.6 +/- 17.2 pmol/l, n=43). Furthermore, in 32 patients with chronic renal failure, greatly increased (p<0.0001) BNP values were found both before (mean +/- SD=88. 1+/- 111.1 pmol/l) and after haemodialysis (mean +/- SD=65.6 +/- 76.7 pmol/l), with a significant reduction after haemodialysis (p=0.0004) compared to pre-haemodialysis. The mean (+/- SD) BNP value found in atrial extracts collected during aorto-coronary bypass operations in 15 patients was 14.5 +/- 51.9 pmol/g of cardiac tissue. Moreover, the mean (+/- SD) tissue levels of BNP in 7 heart transplant recipients were 128.4 +/- 117.2 pmol/g of cardiac tissue in atrium, 68.4 +/- 76.7 pmol/g in ventricle, and 10.9 +/- 8.5 pmol/g in interventricular septum. Finally, BNP values found in cardiac tissues of two subjects collected at autopsy were considerably lower (on average 1/1000) than those observed in cardiac tissues of patients with cardiac diseases. The IRMA method for BNP determination evaluated in this study showed a good degree of sensitivity, precision and practicability. Therefore, this method should be a reliable tool for the measurement of plasma BNP levels for both experimental studies and routine assay. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|