首页 | 本学科首页   官方微博 | 高级检索  
检索        


Results of newborn screening for CDH with and without sonography and correlation of risk factors
Authors:D T?nnis  K Storch  H Ulbrich
Institution:Department of Orthopaedics, St?dtische Kliniken, Dortmund, Federal Republic of Germany.
Abstract:The newborn screening results of 1,310 children examined by Ortolani's and Barlow's manual test, as well as 2,587 children investigated by sonography, have been compared. Of the sonographically pathological hips (technique of Graf), 52.2% had no sign of instability. This was especially true in dysplastic and decentering hip joints, but was found to a smaller degree even in dislocated hips. As a result, twice as many abduction pillows were ordered during the second period. Sonography also detected joints that were immature at birth, but became worse during development (8.9% of hips labeled type 2a, after Graf). A total of 6.54% pathological hips were detected by newborn screening and follow-up of immature hips.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号