首页 | 本学科首页   官方微博 | 高级检索  
     


Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy
Authors:van Geest-Daalderop Johanna H H  Mulder André B  Boonman-de Winter Leandra J M  Hoekstra Martha M C L  van den Besselaar Anton M H P
Affiliation:Thrombosis Service, Department of Laboratory of Clinical Chemistry and Haematology, Jeroen Bosch Hospital, 's-Hertogenbosch, The Netherlands. ankees.vangeest@planet.nl
Abstract:BACKGROUND: The quality of oral anticoagulant therapy management with coumarin derivatives requires reliable results for the prothrombin time/International Normalized Ratio (PT/INR). We assessed the effect on PT/INR of preanalytical variables, including ones related to off-site blood collection and transportation to a laboratory. METHODS: Four laboratories with different combinations of blood collection systems, thromboplastin reagents, and coagulation meters participated. The simulated preanalytical variables included time between blood collection and PT/INR determinations on samples stored at room temperature, at 4-6 degrees C, and at 37 degrees C; mechanical agitation at room temperature, at 4-6 degrees C, and at 37 degrees C; time between centrifugation and PT/INR determination; and times and temperatures of centrifugation. For variables that affected results, the effect of the variable was classified as moderate when <25% of samples showed a change >10% or as large if >25% of samples showed such a change. RESULTS: During the first 6 h after blood collection, INR changed by >10% in <25% of samples (moderate effect) when blood samples were stored at room temperature, 4-6 degrees C, or 37 degrees C with or without mechanical agitation and independent of the time of centrifugation after blood collection. With one combination of materials and preanalytical conditions, a 24-h delay at room temperature or 4-6 degrees C had a large effect, i.e., changes >10% in >25% of samples. In all laboratories, a 24-h delay at 37 degrees C or with mechanical agitation had a large effect. We observed no clinically or statistically relevant INR differences among studied centrifugation conditions (centrifugation temperature, 20 degrees C or no temperature control; centrifugation time, 5 or 10 min). CONCLUSIONS: We recommend a maximum of 6 h between blood collection and PT/INR determination. The impact of a 24-h delay should be investigated for each combination of materials and conditions.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号