首页 | 本学科首页   官方微博 | 高级检索  
     

开放式MRI导航系统导引行肺病变穿刺活检137例
引用本文:吕玉波,李成利,武乐斌,柳明,黄杰,包守刚,亓贞力,曹倩倩,于静. 开放式MRI导航系统导引行肺病变穿刺活检137例[J]. 中华放射学杂志, 2010, 44(11). DOI: 10.3760/cma.j.issn.1005-1201.2010.11.017
作者姓名:吕玉波  李成利  武乐斌  柳明  黄杰  包守刚  亓贞力  曹倩倩  于静
作者单位:山东大学山东省医学影像学研究所MR介入研究室,济南,250021
摘    要:目的 探讨MRI导引下肺穿刺活检术的可行性、准确性及其临床应用价值.方法 应用配备iPath 200光学追踪系统的低场开放式MR仪,对137例肺内结节或肿物患者行穿刺活检术,其中肺内孤立性结节或肿物103例,肺内多发病灶34例;病灶最大径≥3.5 cm的57例、1.5~3.4 cm的71例、≤1.4 cm的9例.结果 病灶最大径≥3.5 cm组、1.5~3.4 cm组、≤1.4 cm组及总的穿刺成功率分别为100.0%(57/57)、98.6%(70/71)、77.8%(7/9)、97.8%(134/137);穿刺组织病理检查诊断恶性肿瘤98例,良性39例;MRI导引肺穿刺活检的敏感度为94.2%(98/104),特异度为100.0%(33/33),准确性为95.6%(131/137),阳性预测值为100.0%(98/98),阴性预测值为84.6%(33/39).结论 开放式MRI导引肺穿刺活检术具有较高的安全性、准确性和有效性,值得在临床进一步推广和应用.

关 键 词:磁共振成像,介入性    活组织检查,针吸

Open MRI navigation system guided needle biopsy of lung lesions: experience with 137 cases
L Yu-bo,LI Cheng-li,WU Le-bin,LIU Ming,HUANG Jie,BAO Shou-gang,QI Zhen-li,CAO Qian-qian,YU Jing. Open MRI navigation system guided needle biopsy of lung lesions: experience with 137 cases[J]. Chinese Journal of Radiology, 2010, 44(11). DOI: 10.3760/cma.j.issn.1005-1201.2010.11.017
Authors:L Yu-bo  LI Cheng-li  WU Le-bin  LIU Ming  HUANG Jie  BAO Shou-gang  QI Zhen-li  CAO Qian-qian  YU Jing
Affiliation:L(U) Yu-bo,LI Cheng-li,WU Le-bin,LIU Ming,HUANG Jie,BAO Shou-gang,QI Zhen-li,CAO Qian-qian,YU Jing
Abstract:Objective To evaluate the feasibility, accuracy and its clinical value of MRI-guided needle biopsy of lung lesions. Methods A total of 137 patients with pulmonary nodules or masses underwent lung biopsy in low-field open MRI equipped with iPath 200 optical tracking systems. Among them, 103 cases had solitary pulmonary lesion; the other 34 cases had multiple foci. The maximum diameter of the lesion was not smaller than 3.5 cm ( ≥ 3.5 cm) in 57 patients, between 1.5 cm and 3.4 cm( 1.5-3.4 cm) in 71 patients, not greater than 1.4 cm ( ≤ 1.4 cm) in 9 patients. Results The puncture success rate was 100.0% (57/57) for lesions ≥3.5 cm, 98.6% (70/71) for lesions 1.5-3.4 cm,77.8% (7/9) for lesions ≤1.4 cm and 97. 8% (134/137) for total cases, respectively. According to the pathological results, pulmonary lesions were malignant in 98 cases and benign in 39 cases. The sensitivity,specificity, accuracy, positive predictive value and negative predictive value of MRI-guided lung biopsy were 94.2%(98/104), 100.0% (33/33), 95.6% (131/137), 100.0% (98/98) and 84.6% (33/39),respectively. Conclusion MRI-guided needle biopsy of lung lesion can be performed precisely in a lowfield open MRI with a low risk of complications. As a supplement to US or CT-guided biopsy, it is worth further promotion and application.
Keywords:Magnetic resonance imaging,interventional  Lung  Biopsy,needle
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号