摘    要:术中准确地评价肠活力是外科医师面临的一个普遍问题。应用兔肠缺血模型,比较静脉荧光素、表面血氧测定和激光多普勒三种技术判断肠活力的精确性。结果:诊断效率静脉荧光素法为78%,表面血氧测定为68%,激光多普勒为95%。后者精确度显著优于前二者,且操作简便、迅速,具有临床应用前景。

关 键 词:肠.小,动物.实验,荧光素,血氧定量法,流量计

Comparison of Methods for Determination of Viability of Intestine
Liao Xian-ping, She Ya-xiong,Li Min..Comparison of Methods for Determination of Viability of Intestine[J].Chinese Journal of Pediatric Surgery,1994,15(6):363-364.
Authors:Liao Xian-ping  She Ya-xiong  Li Min
Abstract:Three methods namely the intravenous fluorescein (FLF), Pulse Oximetry ( POX ) and Laser Doppler Flowmeter (LDF) were used in the determination of the bowel viability on the models of intestinal ischemia in rabbits. The reliability of FLF was 78%. FOX 68%, and LDF 95%. LDF was apparently more sensitive than FLF or POX, and may be the most suitable method for the determination of the ischemic intestine intraoperatively.
Keywords:Intestine  small  Animals  laboratory  Fluoresceins  Oximetry  Flowmeters  