首页 | 本学科首页   官方微博 | 高级检索  
检索        


Mechanical circulatory support with the ABIOMED BVS 5000: the Toronto General Hospital experience
Authors:Lad Vidyadhar  Elhenawy Abdelsalam  Harwood Steve  Maciver Jane  Badiwala Mitesh Vallabh  Vallelonga Mark  Yau Terrence M  Cusimano Robert J  Delgado Diego H  Ross Heather J  Rao Vivek
Institution:Heart Transplant Program, Peter Munk Cardiac Centre, Toronto General Hospital and University of Toronto, Toronto, Ontario.
Abstract:

BACKGROUND

Acute hemodynamic collapse resulting in cardiogenic shock and impending end-organ failure is usually associated with certain death. The introduction of short-term mechanical circulatory support (MCS) devices offers potential therapy to these critically ill patients. The BVS 5000 device (ABIOMED Inc, USA) is widely used in the United States, but rarely in Canada, where device reimbursement remains a barrier.

OBJECTIVE

To present the Toronto General Hospital’s (Toronto, Ontario) initial five-year experience with this device to highlight the indications for use, common complications and overall success rates.

METHODS AND RESULTS

The institutional MCS database from 2001 to 2006 was reviewed, and 18 patients who received 30 devices in a variety of configurations were identified. The most common support configuration consisted of biventricular support (n=12), followed by isolated left ventricular support (n=4) and isolated right ventricular support in two recipients of an implantable long-term left ventricular assist device. Overall survival to device explant or transplant was 55% (n=10), of which five (50%) were successfully discharged from the hospital. The overall survival from device implant to hospital discharge was 28% (five of 18). The most common cause of death was multisystem organ failure.

CONCLUSIONS

MCS with the ABIOMED BVS 5000 can successfully resuscitate critically ill patients; however, earlier institution of this device would avoid irreversible end-organ injury, and lead to higher rates of device explant and hospital discharge. Short-term MCS devices should be available in all cardiac surgical centres in Canada to permit stabilization and evaluation of the acutely ill cardiac patient and subsequent management in a heart transplant facility.
Keywords:Acute cardiogenic shock  Transplantation  Ventricular assist device
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏