Constant vs auto-continuous positive airway pressure in patients with sleep apnea hypopnea syndrome and a high variability in pressure requirement
Authors:Noseda André  Kempenaers Chantal  Kerkhofs Myriam  Braun Stéphanie  Linkowski Paul  Jann Ernest
Institution:Chest Department and Sleep Laboratory, H?pital Erasme, Université Libre de Bruxelles, Brussels, Belgium. andre.noseda@chu-brugmann.be
Abstract:STUDY OBJECTIVES: Auto-continuous positive airway pressure (CPAP) has been reported to have no more efficacy than constant CPAP in unselected patients with sleep apnea hypopnea syndrome (SAHS). The aim of this study was to evaluate patients judged to be good candidates for auto-CPAP because of a high within-night variability in pressure requirement. DESIGN: Single-blind, randomized, cross-over study (2 x 8 weeks) to compare auto-CPAP with constant CPAP. PATIENTS: Outpatients with moderate-to-severe SAHS attending the chest clinic. INTERVENTIONS: Patients were equipped at home in the auto-CPAP mode (model GK418A; Malinckrodt; Nancy, France), using a 4- to 14-cm H(2)O pressure range. Those individuals having a high within-night variability in pressure requirement, assessed at the end of a 14-day run-in period, were included in the cross-over study. Auto-CPAP was compared with constant CPAP (according to a titration night in the sleep laboratory) in terms of compliance, efficacy on apneas (assessed from the pressure monitor), and sleepiness (assessed on the Epworth sleepiness scale). MEASUREMENTS AND RESULTS: Of 90 consecutive patients with SAHS, 27 patients were selected for a within-night variability in pressure requirement exceeding a given threshold. After completion of the cross-over, 24 patients were evaluable. The median percentage of nights the machine was used was 95.5% (range, 45 to 100%) on constant CPAP, and 96.5% (range, 40 to 100%) on auto-CPAP; the median apnea index recorded by the device was 0.40/h (range, 0 to 2.40/h) on constant CPAP, and 0.45/h (range, 0 to 5.80/h) on auto-CPAP (differences not significant). The mean Epworth sleepiness score was significantly (p < 0.01) lower on auto-CPAP (5.1; SD, 2.8) than on constant CPAP (6.1; SD, 2.8). CONCLUSIONS: In patients selected for a high within-night variability in pressure requirement, auto-CPAP administered via a GK418A device was equivalent to constant CPAP based on a titration night in the sleep laboratory. Subjective ratings for sleepiness were slightly lower on auto-CPAP.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号