首页 | 本学科首页   官方微博 | 高级检索  
检索        


The accuracy of integrated PET-CT compared with dedicated PET alone for the staging of patients with nonsmall cell lung cancer
Authors:Cerfolio Robert James  Ojha Buddhiwardhani  Bryant Ayesha S  Raghuveer Vanguru  Mountz James M  Bartolucci Alfred A
Institution:a Section of Thoracic Surgery, University of Alabama at Birmingham, and Division of Cardiothoracic Surgery, Department of Surgery, Birmingham Veterans Administration Hospital, Birmingham, Alabama, USA
b Department of Epidemiology, University of Alabama at Birmingham, School of Public Health, Birmingham, Alabama, USA
c Division of Clinical Nuclear Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
d Department of Biostatistics, University of Alabama at Birmingham, School of Public Health, Birmingham, Alabama, USA
Abstract:

Background

The treatment of patients with nonsmall cell lung cancer (NSCLC) is determined by the stage. We evaluated the accuracy of staging using integrated positron emission tomography (PET) and computed tomography (CT) and compared it with dedicated PET visually correlated with CT scan.

Methods

A prospective blinded trial was performed on a consecutive series of patients with NSCLC. Patients underwent integrated PET-CT scanning with 2-18F]-fluoro-2-deoxy-D-glucose (FDG-18). A radiologist assigned the T, N and M status. No sooner than 2 weeks the same radiologist read the dedicated PET alone, without the integrated CT images and a T, N and M status was assigned again. The most recent CT scan was available and visually correlated with both studies. All patients underwent biopsies of suspicious N2 or N3 lymph node or distant metastases and if negative, pulmonary resection with lymphadenectomy was performed.

Results

There were 129 patients. Integrated PET-CT is a better predictor than PET for all stages of cancer and achieved statistical significance for stage I (52% versus 33%, p = 0.03) and for stage II (70% versus 36%, p = 0.04). It also is a better overall predictor for T status (70% versus 47%, p = 0.001) and the N status (78% versus 56%, p = 0.008). Nodal analysis shows that integrated PET-CT was more accurate for the total N2 nodes (96% versus 93%, p = 0.01) and for the total N1 nodes (90% versus 80%, p = 0.001). It was also more sensitive, specific, and had a higher positive predictive value for both N2 and N1 nodes (p < 0.05 for all). Integrated PET-CT is significantly more sensitive at the 4R, 5, 7, 10L and 11 stations and more accurate at the 7 and 11 lymph nodes stations than dedicated PET.

Conclusions

Integrated PET-CT using FDG-18 better predicts stage I and II disease as well as the T and N status of patients with NSCLC when compared with dedicated PET alone. It is more accurate at some nodal stations but still only achieves an accuracy of 96% and 90% for the N2 and N1 nodes, respectively.
Keywords:10
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号