首页 | 本学科首页   官方微博 | 高级检索  
     


Postoperative assessment of the univentricular repair by dynamic radionuclide studies
Authors:Chowdhury Ujjwal K  Mishra Pankaj K  Sharma Rajesh  Airan Balram  Subramaniam Ganapathy K  Kothari Shyam S  Bhan Anil  Patel Chetan D  Venugopal Panangipalli
Affiliation:a Departments of Cardiothoracic and Vascular Surgery, Cardiothoracic Centre, All India Institute of Medical Sciences, New Delhi, India
b Department of Cardiology, Cardiothoracic Centre, All India Institute of Medical Sciences, New Delhi, India
c Department of Nuclear Medicine, Cardiothoracic Centre, All India Institute of Medical Sciences, New Delhi, India
Abstract:

Background

The purpose of this investigation was to determine the role of radionuclide studies in evaluating postoperative Fontan hemodynamics and to quantify its diagnostic accuracy.

Methods

One hundred five patients (105), aged 11 months to 35 years old, who had undergone univentricular repair, underwent first-pass and multigated acquisition scan 1 month to 10 years after univentricular repair. Forty-five patients with evidence of Fontan failure underwent radionuclide studies using Technetium-99 m as well as cardiac catheterization (group 1). The remaining sixty randomly selected patients with excellent functional status received radionuclide studies alone (group 2). The receiver operating characteristic curve analysis was done to quantify the diagnostic accuracy of the first-pass study.

Results

There was paradoxical filling of the right lung after femoral injection in all cases of tunnel or conduit obstruction. A first-pass transit time of 16 to 25 seconds (mean ± standard deviation [SD] = 18.82 ± 2.69) was always associated with Fontan failure and high right atrial pressure (range = 20 to 24 mm Hg, mean ± SD = 22.02 ± 1.58). A first-pass transit time of 16 seconds was associated with a sensitivity of 100% and a specificity of 93.33%. The predictive accuracy of a positive or negative result was 91.8% and 100% respectively. The area measured under the receiver operating characteristic curve indicates that 99.41% (SE ± 0.0035) of the time, the value of first-pass time is higher for the Fontan failure group (group 1) compared to the normal group (group 2; p = 0.000).

Conclusions

Our data indicate that Fontan circuit can be reliably evaluated for both anatomic and functional flaws by radionuclide studies; radionuclide first-pass time may be used to predict the chances of Fontan failure postoperatively as well as its presence; and in the presence of atrial fibrillation with fast ventricular rate, analysis using first-pass radionuclide may be impossible and gated equilibrium radionuclide angiocardiography may be the preferred method. Inspection of the systemic ventricular time-activity curve is of crucial importance in this regard.
Keywords:21
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号