Diagnostic Accuracy of Cardiovascular Magnetic Resonance for Cardiac Transplant Rejection: A Meta-Analysis |
| |
Institution: | 1. Department of Imaging, Mark Taper Imaging Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA;2. Department of Cardiac Sciences, University of Calgary, Calgary, Alberta, Canada;3. Smidt Heart Institute, Cedars-Sinai Heart Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA |
| |
Abstract: | ObjectivesThe aim of this meta-analysis was to assess the diagnostic performance of various CMR imaging parameters for evaluating acute cardiac transplant rejection.BackgroundEndomyocardial biopsy is the current gold standard for detection of acute cardiac transplant rejection. Cardiac magnetic resonance (CMR) is uniquely capable of myocardial tissue characterization and may be useful as a noninvasive alternative for the diagnosis of graft rejection.MethodsPubMed and Web of Science were searched for relevant publications reporting on the use of CMR myocardial tissue characterization for detection of acute cardiac transplant rejection with endomyocardial biopsy as the reference standard. Pooled sensitivity, specificity, and hierarchical modeling–based summary receiver-operating characteristic curves were calculated.ResultsOf 478 papers, 10 studies comprising 564 patients were included. The sensitivity and specificity for the detection of acute cardiac transplant rejection were 84.6 (95% CI: 65.6-94.0) and 70.1 (95% CI: 54.2-82.2) for T1, 86.5 (95% CI: 72.1-94.1) and 85.9 (95% CI: 65.2-94.6) for T2, 91.3 (95% CI: 63.9-98.4) and 67.6 (95% CI: 56.1-77.4) for extracellular volume fraction (ECV), and 50.1 (95% CI: 31.2-68.9) and 60.2 (95% CI: 36.7-79.7) for late gadolinium enhancement (LGE). The areas under the hierarchical modeling–based summary receiver-operating characteristic curve were 0.84 (95% CI: 0.81-0.87) for T1, 0.92 (95% CI: 0.89-94) for T2, 0.78 (95% CI: 0.74-0.81) for ECV, and 0.56 (95% CI: 0.51-0.60) for LGE. T2 values demonstrated the highest diagnostic accuracy, followed by native T1, ECV, and LGE (all P values <0.001 for T1, ECV, and LGE vs T2).ConclusionsT2 mapping demonstrated higher diagnostic accuracy than other CMR techniques. Native T1 and ECV provide high diagnostic use but lower diagnostic accuracy compared with T2, which was related primarily to lower specificity. LGE showed poor diagnostic performance for detection of rejection. |
| |
Keywords: | CMR cardiac transplant meta-analysis transplant rejection AUC"} {"#name":"keyword" "$":{"id":"kwrd0035"} "$$":[{"#name":"text" "_":"area under the hierarchical modeling–based summary receiver-operating characteristic curve CMR"} {"#name":"keyword" "$":{"id":"kwrd0045"} "$$":[{"#name":"text" "_":"cardiac magnetic resonance DOR"} {"#name":"keyword" "$":{"id":"kwrd0055"} "$$":[{"#name":"text" "_":"diagnostic odds ratio ECV"} {"#name":"keyword" "$":{"id":"kwrd0065"} "$$":[{"#name":"text" "_":"extracellular volume fraction EMB"} {"#name":"keyword" "$":{"id":"kwrd0075"} "$$":[{"#name":"text" "_":"endomyocardial biopsy HSROC"} {"#name":"keyword" "$":{"id":"kwrd0085"} "$$":[{"#name":"text" "_":"hierarchical modeling–based summary receiver-operating characteristic ISHLT"} {"#name":"keyword" "$":{"id":"kwrd0095"} "$$":[{"#name":"text" "_":"International Society for Heart and Lung Transplantation LGE"} {"#name":"keyword" "$":{"id":"kwrd0105"} "$$":[{"#name":"text" "_":"late gadolinium enhancement NLR"} {"#name":"keyword" "$":{"id":"kwrd0115"} "$$":[{"#name":"text" "_":"negative likelihood ratio PLR"} {"#name":"keyword" "$":{"id":"kwrd0125"} "$$":[{"#name":"text" "_":"positive likelihood ratio ROC"} {"#name":"keyword" "$":{"id":"kwrd0135"} "$$":[{"#name":"text" "_":"receiver-operating characteristic |
本文献已被 ScienceDirect 等数据库收录! |
|