Patient-Specific Implantation Technique to Obtain Neo-Commissural Alignment With Self-Expanding Transcatheter Aortic Valves |
| |
Affiliation: | The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark |
| |
Abstract: | ObjectivesThe authors sought to investigate whether a patient-specific implantation technique during transcatheter aortic valve replacement (TAVR) can result in a safe and reproducible neo-commissural alignment of self-expanding transcatheter heart valves (THVs).BackgroundTo date, little attention has been paid to neo-commissural alignment during TAVR.MethodsA fluoroscopy-based, patient- and valve-specific TAVR implantation technique was applied in 60 patients treated with 3 different self-expanding THV platforms (Evolut R/PRO, Medtronic; ACURATE neo2, Boston Scientific; and Portico, Abbott—20 patients in each group). Post-TAVR cardiac computed tomography was used to assess THV neo-commissural alignment.ResultsConsidering all 60 patients, ≤mild commissural misalignment (CMA <30°) was obtained in 53 patients (88%) using this modified TAVR implantation technique—in 36 patients (60%), optimal commissural alignment (<15°) was obtained. In 2 patients, cardiac computed tomography revealed severe CMA (>45°) with overlap between the coronary ostia and THV commissures. Using the ACURATE neo2 platform, operators succeeded in avoiding ≥moderate CMA in all 20 cases. When analyzing those cases in which the optimal amount of THV rotation could be assessed and applied before THV expansion (n = 52; 87%), the success rate of TAVR with ≤mild CMA was 98%. No procedure- or valve-related complications occurred in this study cohort.ConclusionsA patient-specific TAVR implantation technique aiming to obtain neo-commissural alignment is feasible and safe, and aides to prevent THV implantations with overlap between the coronary ostia and THV commissures. Optimized TAVR devices and design may further improve the success rate of TAVR with neo-commissural alignment. |
| |
Keywords: | cardiac computed tomography commissural alignment implantation technique patient-specific TAVR CMA" },{" #name" :" keyword" ," $" :{" id" :" kwrd0040" }," $$" :[{" #name" :" text" ," _" :" commissural misalignment CT" },{" #name" :" keyword" ," $" :{" id" :" kwrd0050" }," $$" :[{" #name" :" text" ," _" :" computed tomography LCC" },{" #name" :" keyword" ," $" :{" id" :" kwrd0060" }," $$" :[{" #name" :" text" ," _" :" left coronary cusp NCC" },{" #name" :" keyword" ," $" :{" id" :" kwrd0070" }," $$" :[{" #name" :" text" ," _" :" noncoronary cusp RAO" },{" #name" :" keyword" ," $" :{" id" :" kwrd0080" }," $$" :[{" #name" :" text" ," _" :" right anterior oblique RCA" },{" #name" :" keyword" ," $" :{" id" :" kwrd0090" }," $$" :[{" #name" :" text" ," _" :" right coronary artery RCC" },{" #name" :" keyword" ," $" :{" id" :" kwrd0100" }," $$" :[{" #name" :" text" ," _" :" right coronary cusp TAVR" },{" #name" :" keyword" ," $" :{" id" :" kwrd0110" }," $$" :[{" #name" :" text" ," _" :" transcatheter aortic valve replacement THV" },{" #name" :" keyword" ," $" :{" id" :" kwrd0120" }," $$" :[{" #name" :" text" ," _" :" transcatheter heart valve |
本文献已被 ScienceDirect 等数据库收录! |
|