虹膜夹型人工晶状体矫正高度近视的前节OCT检查分析
引用本文:王丽强,黄一飞,王玮,杨炳健,钱海燕,王宁.虹膜夹型人工晶状体矫正高度近视的前节OCT检查分析[J].国际眼科杂志,2006,6(6):1252-1254.
作者姓名:王丽强  黄一飞  王玮  杨炳健  钱海燕  王宁
作者单位:100853,中国北京市,解放军总医院眼科
摘    要:目的:使用前节OCT分析高度近视植入虹膜夹型人工晶状体后眼内的结构变化。方法:植入前房晶状体矫正高度近视6眼(11.5D至22.0D),使用前节OCT采集前节图像测量术前前房深度,术后人工晶状体与角膜内皮间距离(内皮—晶状体距离),人工晶状体与正常晶状体间距离。结果:术前前房深度为3.27~3.91mm,术后内皮—晶状体距离为2.07~2.24mm。人工晶状体后表面与正常晶状体间的距离为0.82~1.32mm。图像显示虹膜色素层没有明显改变。结论:前房深度较术前减少36.1%~44.6%。前节OCT对于检测虹膜夹型前房晶状体的位置有帮助。

关 键 词:前节OCT  虹膜夹型人工晶状体  高度近视
收稿时间:2006-09-26
修稿时间:2006-09-262006-12-11

AC OCT of the anterior chamber iris-fixated phakic intraocular lens in high myopia eyes
Li-Qiang Wang,Yi-Fei Huang,Wei Wang,Bing-Jian Yang,Hai-Yan Qian,Ning Wang.AC OCT of the anterior chamber iris-fixated phakic intraocular lens in high myopia eyes[J].International Journal of Ophthalmology,2006,6(6):1252-1254.
Authors:Li-Qiang Wang  Yi-Fei Huang  Wei Wang  Bing-Jian Yang  Hai-Yan Qian  Ning Wang
Institution:Department of Ophthalmology, General Hospital of Chinese PLA, Beijing 100853, China
Abstract:AIM: To study the in situ relative intraocular position of the iris-claw phakic intraocular lens(PIOL)for high myopia using an anterior chamber optical coherence tomography(AC OCT) prototype. METHODS: Six PIOLs (11.50 to 22.00D lens powers) were implanted in phakic myopic eyes. Using AC OCT, tomography was taken in the anterior chamber to measure the preoperative anterior chamber depth, postoperative distance between the PIOL and the corneal endothelium (endothelial-optic distance), and the postoperative distance between the PIOL and the crystalline lens. RESULTS: Preoperative anterior chamber depth ranged from 3.27 to 3.91mm and the postoperative endothelial-optic distance measured 2.07 to 2.24mm. The distance between the crystalline lens and the posterior surface of the IOL ranged from 0.82 to 1.32mm. Several tomography revealed the position of the PIOL on the iris. The pigment layer of the iris did not seem to be disturbed by the presence of the PIOL. CONCLUSION: The original anterior chamber depths were reduced by 36.1% to 44.6% after implantation. This study of 6 eyes revealed that tomography taken by AC OCT are useful in verifying the intraocular position of the PIOL within the anterior chamber. Adequate space was maintained between the iris-fixated phakic intraocular lens and the corneal endothelium, angle, and crystalline lens.
Keywords:anterior chamber optical coherence tomography  iris-claw phakic intraocular lens  high myopia