首页 | 本学科首页   官方微博 | 高级检索  
     


Effects of infrasound on the Rota-Rod Treadmill performance of rats
Authors:KŌtarŌ Yamamura  Reiko Kishi
Affiliation:(1) Department of Public Health, Sapporo Medical College, S 1, W 17, 060 Sapporo, Japan
Abstract:Summary The present study was designed to evaluate the effects of infrasound on behavioral performance in rats. The rats were divided into two groups, one selected for good performance (six rats: superior group) and the other for poor performance (six rats: inferior group) on the Rota-Rod Treadmill.Exposure conditions were as follows:Exp. 1 Control (150 min), Exp. 2 Exposure to infrasound with a main frequency of 16 Hz and a sound pressure level of 105 dB (S.P.L.) (70 min), Exp. 3 Exposure to infrasound with a main frequency of 16 Hz and a sound pressure level of 95 dB (S.P.L.) (70 min), Exp. 4 Exposure to infrasound with a main frequency of 16 Hz and a sound pressure level of 85 dB (S.P.L.) (150 min), Exp. 5 Exposure to infrasound with a main frequency of 16 Hz and a sound pressure level of 75 dB (S.P.L.) (150 min), Exp. 6 Exposure to Pink Noise of 72 dB (A) (70 min).Comparison of the pre-exposure endurance time (Maximum: 2 min) on the Rota-Rod Treadmill with endurance after exposure to infrasound showed that the endurance time of the superior group after exposure to 16 Hz, 105 dB was not reduced. The endurance of the inferior group was reduced by exposure to 16 Hz, 105 dB after 10 min, to 16 Hz, 95 dB after 70 min, and to 16 Hz, 85 dB after 150 min.
Keywords:Infrasound  Rota-Rod-Treadmill  Endurance time
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏