首页 | 本学科首页   官方微博 | 高级检索  
     


Impact of Repositioning on Outcomes Following Transcatheter Aortic Valve Replacement With a Self-Expandable Valve
Affiliation:1. Harrington Heart and Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, Ohio;2. Department of Interventional Cardiology, OhioHealth Riverside Methodist, Columbus, Ohio;3. Departments of Cardiac Surgery, University of Michigan Hospitals, Ann Arbor, Michigan;4. Department of Cardiothoracic Surgery, Houston Methodist DeBakey Heart and Vascular Center, Houston, Texas;5. Departments of Internal Medicine (Cardiology) and Cardiac Surgery, Yale University School of Medicine, New Haven, Connecticut;6. Department of Biostatistics, Medtronic Statistical Services, Minneapolis, Minnesota;7. Department of Interventional Cardiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts
Abstract:ObjectivesThis study sought to compare outcomes following transcatheter aortic valve replacement when valve repositioning was performed (repositioned group) versus procedures without repositioning (nonrepositioned group).BackgroundThe Evolut R and Evolut PRO valves were designed to allow repositioning during deployment, yet the effect of repositioning on clinical outcomes remains unclear.MethodsPatients implanted with the Evolut R or PRO valve from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial continued access study and the Evolut Low Risk Trial between June 2016 and November 2018 were combined. Baseline multidetector computed tomography data were analyzed for the Evolut Low Risk Trial patients. The primary outcomes were the rate of all-cause mortality and the rate of disabling stroke 30 days. Secondary outcomes were per Valve Academic Research Consortium-2.ResultsThe Evolut R or PRO valve was implanted in 946 patients, and repositioning was performed in 318 (33.6%). Compared with patients in the nonrepositioned group, patients in the repositioned group had lower Society of Thoracic Surgeons score (2.3 ± 1.3% vs. 2.6 ± 1.4%; p < 0.001) and fewer prior percutaneous coronary interventions (11.9% vs. 19.7%; p = 0.003). There were no differences in baseline multidetector computed tomography parameters between groups. There were no differences in the primary outcome of death (0.3% vs. 0.3%; p = 0.99) or disabling stroke (0.3% vs. 0.5%; p = 0.71) at 30 days or 1 year (1.9% vs. 2.9%; p = 0.44; and 0.8% vs. 0.9%%; p = 0.79, respectively).ConclusionsThe utilization of the repositioning feature of the Evolut valves was safe, and no differences in death or disabling stroke were observed at 30 days or 1 year between groups. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283; Safety and Efficacy Study of the Medtronic CoreValve® System In the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910)
Keywords:recapture  repositioning  resheath  self-expandable valve  TAVR  transcatheter aortic valve replacement  transcatheter heart valve  CAS"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0050"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  continued access study  IQR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0060"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  interquartile range  LVEF"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0070"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  left ventricular ejection fraction  LVOT"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0080"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  left ventricular outflow tract  MDCT"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0090"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  multidetector computed tomography  NRP"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0100"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  nonrepositioned  PPI"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0110"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  permanent pacemaker implantation  RP"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0120"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  repositioned  TAVR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0130"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  transcatheter aortic valve replacement
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号