Long-Term Outcomes of Biodegradable Versus Second-Generation Durable Polymer Drug-Eluting Stent Implantations for Myocardial Infarction |
| |
Institution: | 1. Department of Cardiology and Medical Research Institute, Pusan National University Hospital, Busan, South Korea;2. Health Promotion Center, Pusan National University Hospital, Busan, South Korea;3. Department of Biostatistics, Pusan National University Hospital, Busan, South Korea;4. Department of Cardiology, Chonnam National University Hospital, Gwangju, South Korea |
| |
Abstract: | ObjectivesThis study sought to compare outcomes between biodegradable polymer drug-eluting stent (BP-DES) and second-generation durable polymer drug-eluting stent (DP-DES) implantations for acute myocardial infarction (MI) using a nationwide dataset.BackgroundData regarding outcomes of BP-DES versus second-generation DP-DES are inconclusive.MethodsAmong 13,104 patients with acute MI in a nationwide registry who underwent percutaneous coronary intervention (November 2011 to December 2015), BP-DES and second-generation DP-DES were implanted in 2,261 (21.7%) and 8,182 patients (78.3%), respectively. Major adverse cardiac events (MACE) (all-cause death, recurrent MI, or any revascularization) were compared in multivariable Cox regression, propensity score (PS) matched, and underwent PS-adjusted analyses.ResultsMACE occurred in 1,492 (14.3%) patients during a median 723-day follow-up. MACE were less frequent with BP-DES implantation than with second-generation DP-DES implantation (entire cohort hazard ratio HR]: 0.845; 95% confidence interval CI]: 0.740 to 0.965; PS-matched HR: 0.669; 95% CI: 0.550 to 0.814). Risk of all-cause death (entire cohort HR: 0.831; 95% CI: 0.692 to 0.997; PS-matched HR: 0.752; 95% CI: 0.495 to 0.931), cardiac death (entire cohort HR: 0.685; 95% CI: 0.542 to 0.865; PS-matched HR: 0.613; 95% CI: 0.463 to 0.872), recurrent MI (entire cohort HR: 0.662; 95% CI: 0.466 to 0.941; PS-matched HR: 0.611; 95% CI: 0.427 to 0.898), and heart failure readmission (entire cohort HR: 0.625; 95% CI: 0.447 to 0.875; PS-matched HR: 0.584; 95% CI: 0.385 to 0.887) was less with BP-DES implantation. There were no significant group differences in the incidences of any revascularization, stroke, and definite or probable stent thrombosis.ConclusionsIn patients with acute MI who underwent percutaneous coronary intervention, BP-DES implantation is associated with improved outcomes compared with second-generation DP-DES implantation. |
| |
Keywords: | acute myocardial infarction biodegradable polymer drug-eluting stent clinical outcome second-generation durable polymer drug-eluting stent BP-DES"} {"#name":"keyword" "$":{"id":"kwrd0035"} "$$":[{"#name":"text" "_":"biodegradable polymer drug-eluting stent DAPT"} {"#name":"keyword" "$":{"id":"kwrd0055"} "$$":[{"#name":"text" "_":"dual antiplatelet therapy DP-DES"} {"#name":"keyword" "$":{"id":"kwrd0065"} "$$":[{"#name":"text" "_":"durable polymer drug-eluting stent HF"} {"#name":"keyword" "$":{"id":"kwrd0075"} "$$":[{"#name":"text" "_":"heart failure MACE"} {"#name":"keyword" "$":{"id":"kwrd0095"} "$$":[{"#name":"text" "_":"major adverse cardiac event MI"} {"#name":"keyword" "$":{"id":"kwrd0105"} "$$":[{"#name":"text" "_":"myocardial infarction NACE"} {"#name":"keyword" "$":{"id":"kwrd0115"} "$$":[{"#name":"text" "_":"net adverse clinical event PCI"} {"#name":"keyword" "$":{"id":"kwrd0125"} "$$":[{"#name":"text" "_":"percutaneous coronary intervention PS"} {"#name":"keyword" "$":{"id":"kwrd0135"} "$$":[{"#name":"text" "_":"propensity score ST"} {"#name":"keyword" "$":{"id":"kwrd0145"} "$$":[{"#name":"text" "_":"stent thrombosis STEMI"} {"#name":"keyword" "$":{"id":"kwrd0155"} "$$":[{"#name":"text" "_":"ST-segment elevation myocardial infarction VLST"} {"#name":"keyword" "$":{"id":"kwrd0165"} "$$":[{"#name":"text" "_":"very late stent thrombosis |
本文献已被 ScienceDirect 等数据库收录! |
|