首页 | 本学科首页   官方微博 | 高级检索  
     


Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis
Affiliation:1. Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia;2. MedStar Health Research Institute, MedStar Washington Hospital Center, Washington, District of Columbia;3. Department of Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia;4. Division of Cardiology, The Miriam Hospital, Providence, Rhode Island;5. Division of Cardiothoracic Surgery, Lifespan Cardiovascular Institute, Providence, Rhode Island;6. Department of Medicine, Stony Brook Hospital, Stony Brook, New York;7. Department of Surgery, Stony Brook Hospital, Stony Brook, New York;8. Department of Cardiology, Henrico Doctors’ Hospital, Richmond, Virginia;9. Department of Cardiothoracic Surgery, Henrico Doctors’ Hospital, Richmond, Virginia;10. Sutter Medical Center, Sacramento, Sutter Heart and Vascular Institute, Research, Sacramento, California;11. St. John Heart Institute Cardiovascular Consultants, St. John Health System, Tulsa, Oklahoma;12. St. John Clinic Cardiovascular Surgery, St. John Heart Institute Cardiovascular Consultants, St. John Health System, Tulsa, Oklahoma;13. Department of Cardiac Surgery, MedStar Washington Hospital Center, Washington, District of Columbia;14. Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
Abstract:ObjectivesThe aim of this study was to evaluate clinical outcomes and transcatheter heart valve hemodynamic parameters after transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic stenosis (AS).BackgroundTAVR is approved for low-risk patients in the United States. However, patients with bicuspid AS were excluded from the randomized cohorts of the pivotal low-risk trials.MethodsThe LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and was the first and only U.S. Food and Drug Administration–approved investigational device exemption trial to evaluate the feasibility of TAVR with either balloon-expandable or self-expanding valves in low-risk patients with bicuspid AS. The primary endpoint was all-cause mortality at 30 days. Baseline and follow-up echocardiography and computed tomography to detect leaflet thickening were analyzed in an independent core laboratory.ResultsSixty-one low-risk patients with symptomatic, severe AS and bicuspid aortic valves (78.3% Sievers type 1 morphology) underwent TAVR at 6 centers from 2016 to 2019. The mean age was 68.6 years, and 42.6% were men. At 30 days, there was zero mortality and no disabling strokes. The rate of new permanent pacemaker implantation was 13.1%; just 1 patient had a moderate paravalvular leak at 30 days. Hypoattenuated leaflet thickening was observed in 10% of patients at 30 days.ConclusionsTAVR appears to be safe in patients with bicuspid AS, with short length of hospital stay, zero mortality, and no disabling strokes at 30 days. Subclinical leaflet thrombosis was observed in a minority of patients at 30 days but did not appear to be associated with clinical events.
Keywords:aortic stenosis  bicuspid aortic valve  low risk  transcatheter aortic valve replacement  AS"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0035"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  aortic stenosis  CT"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0045"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  computed tomographic  FDA"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0055"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  U.S. Food and Drug Administration  HALT"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0065"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  hypoattenuated leaflet thickening  PPM"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0075"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  permanent pacemaker  PVL"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0085"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  paravalvular leak  SAVR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0095"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  surgical aortic valve replacement  STS"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0105"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Society of Thoracic Surgeons  TAVR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0115"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  transcatheter aortic valve replacement  THV"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0125"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  transcatheter heart valve
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号