首页 | 本学科首页   官方微博 | 高级检索  
检索        


Diagnostic Accuracy of FDG PET/CT in Suspected LVAD Infections: A Case Series,Systematic Review,and Meta-Analysis
Institution:1. Division of Cardiovascular Medicine, Department of Medicine, University of Michigan, Ann Arbor, Michigan;2. Department of Medicine, Fort Belvoir Community Hospital, Fort Belvoir, Virginia;3. Department of Medicine, Uniformed Services University, Bethesda, Maryland;4. Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan
Abstract:ObjectivesThe purpose of this study was to describe our experience with fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography computed tomography (PET/CT) in diagnosing left ventricular assist device (LVAD) infections and perform a meta-analysis of published studies to determine overall diagnostic accuracy.BackgroundDevice-related infections are a common complication of LVADs and are linked to worse outcomes. Diagnosis of LVAD infections remains challenging. FDG PET/CT has demonstrated good diagnostic accuracy in several other infectious conditions.MethodsThis was a single-center, retrospective case series of FDG PET/CT scans in suspected LVAD infection between September 2015 and February 2018. A systematic review of PubMed from database inception through March 2018 was also conducted to identify additional studies.ResultsNineteen FDG PET/CT scans were identified for the retrospective case series. The systematic review identified an additional 3 publications, for a total of 4 studies involving 119 scans assessing diagnostic performance. Axial (n = 36) and centrifugal (n = 83) flow LVADs were represented. Pooled sensitivity was 92% (95% confidence interval CI]: 82% to 97%) and specificity was 83% (95% CI: 24% to 99%) for FDG PET/CT in diagnosing LVAD infections. Summary receiver-operating characteristic curve analysis demonstrated an AUC of 0.94 (95% CI: 0.91 to 0.95).ConclusionsFDG PET/CT for suspected LVAD infections demonstrates good diagnostic accuracy, with overall high sensitivity but variable specificity.
Keywords:diagnostic testing  heart failure  infection  left ventricular assist device  meta-analysis  positron emission tomography  AUC"}  {"#name":"keyword"  "$":{"id":"kwrd0045"}  "$$":[{"#name":"text"  "_":"area under the curve  CI"}  {"#name":"keyword"  "$":{"id":"kwrd0055"}  "$$":[{"#name":"text"  "_":"confidence interval  CT"}  {"#name":"keyword"  "$":{"id":"kwrd0065"}  "$$":[{"#name":"text"  "_":"computed tomography  FDG"}  {"#name":"keyword"  "$":{"id":"kwrd0075"}  "$$":[{"#name":"text"  "_":"fluorine-18 fluorodeoxyglucose  LVAD"}  {"#name":"keyword"  "$":{"id":"kwrd0085"}  "$$":[{"#name":"text"  "_":"left ventricular assist device  PET"}  {"#name":"keyword"  "$":{"id":"kwrd0095"}  "$$":[{"#name":"text"  "_":"positron emission tomography  SROC"}  {"#name":"keyword"  "$":{"id":"kwrd0105"}  "$$":[{"#name":"text"  "_":"summary receiver-operating characteristic  TEE"}  {"#name":"keyword"  "$":{"id":"kwrd0115"}  "$$":[{"#name":"text"  "_":"transesophageal echocardiography
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号