首页 | 本学科首页   官方微博 | 高级检索  
检索        


Quadtree-based data compression of abdominal CT images
Authors:E J Halpern  H M Levy  J H Newhouse  E S Amis  L M Sanders  I K Mun
Institution:Department of Radiology, Columbia Presbyterian Medical Center, New York, NY 10032.
Abstract:An ROC study was performed to evaluate the effect of quadtree-based data compression on the diagnostic yield of CT images. Seventy images were selected from a series of consecutive abdominal/pelvic CT scans. Following the application of quadtree-based compression, all images were reviewed independently by three radiologists. The images were analyzed at six decreasing irreversible compression ratios (30.6:1 to 7.4:1), as well as after reversible compression (2.9:1). ROC curves reveal a gradual decrease in clinical accuracy with increasing compression ratios. At a compression ratio of 7.4:1, sensitivity for all major abnormalities was 99% with a specificity of 93%. As the compression ratio was increased to 30.6:1, sensitivity and specificity dropped to 75% and 83% respectively. Execution times for compression and decompression of the CT images with a PC-AT based digital radiography system varied from 24.7 to 18.5 seconds and from 16.2 to 5.1 seconds respectively, decreasing with higher levels of compression. We conclude that quadtree-based compression of abdominal CT images may have practical applications for a PC based digital radiography system.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏