物理型和中间型人工肝对肝衰竭支持效果的比较研究
引用本文:何念海,王英杰,刘俊,李佳佳,刘国栋,王宇明. 物理型和中间型人工肝对肝衰竭支持效果的比较研究[J]. 西南国防医药, 2004, 14(4): 363-366
作者姓名:何念海  王英杰  刘俊  李佳佳  刘国栋  王宇明
作者单位:第三军医大学西南医院全军感染病研究所,重庆,400038
基金项目:国家自然科学基金资助项目 ,NO :30 0 2 70 0 1
摘    要:目的 :比较物理型 (血液灌流吸附 )及中间型 (血浆置换 )人工肝支持方法对肝衰竭患者肝功能的支持效果、安全性。方法 :4 1例重型肝炎肝衰竭患者分别进行血液灌流吸附 (2 4例 5 2例次 )和血浆置换 (17例 3 6例次 )治疗 ,观察治疗前后患者临床症状体征变化 ,比较治疗前后肝肾功能、血常规、PT变化。结果 :血液灌流吸附和血浆置换治疗后 ,患者的临床症状均有不同程度改善。两种方法治疗后转氨酶、总胆红素、直接胆红素下降均有显著性意义 (P <0 0 5或P <0 0 1) ,血浆置换治疗后凝血酶原时间、总蛋白下降 ,凝血酶原活动度升高均有显著性意义 (P <0 0 5或P <0 0 1) ,比较两种治疗方法的上述指标变化程度均无显著性意义 (P >0 1或P >0 2 5 )。两种治疗方法的不良反应均较轻。结论 :物理型、中间型人工肝对重型肝炎肝衰竭患者的肝功能均有肯定的支持效果 ,中间型人工肝的支持效果与物理型人工肝无显著差异。

关 键 词:肝功能衰竭  人工肝  肝支持
文章编号:1004-0188(2004)04-0363-04
修稿时间:2004-03-01

Comparison study of physical and middle artificial liver in treatment of hepatic failure
HE Nian - hai,WANG Ying - jie,LIU Jun,LI Jia - jia,LIU Guo - dong,WANG Yu - ming.Research Institute of Infectious Disease of PLA,Southwest Hospital,Third Military Medical University,Chongqing,.. Comparison study of physical and middle artificial liver in treatment of hepatic failure[J]. Medical Journal of National Defending forces in Southwest China, 2004, 14(4): 363-366
Authors:HE Nian - hai  WANG Ying - jie  LIU Jun  LI Jia - jia  LIU Guo - dong  WANG Yu - ming.Research Institute of Infectious Disease of PLA  Southwest Hospital  Third Military Medical University  Chongqing  .
Affiliation:HE Nian - hai,WANG Ying - jie,LIU Jun,LI Jia - jia,LIU Guo - dong,WANG Yu - ming.Research Institute of Infectious Disease of PLA,Southwest Hospital,Third Military Medical University,Chongqing,400038.
Abstract:Objective: To compare the efficacy and safety between physical artificial liver(hemoperfusion adsorption) and middle artificial liver(plasma exchange) in treatment of hepatic failure. Methods: Forty - one patients with hepatic failure were treated by hemoperfusion adsorption(24 cases conducted 52 time treatments) or plasma exchange(17 cases conducted 36 time treatments). The liver function, renal function, blood routine tests, prothrombin time(PT) and prothrombin activity(PTa) of two groups were examined before and after the treatment. Meanwhile, the changes of symptoms and signs of these subjects were observed closely. Results: Symptoms of all patients improved after the treatment. Compared with those before the treatment, the levels of serum aminotransferase, total bilirubin, direct bilurubin of two groups decreased after the treatment(p<0.05 or 0.01). In the plasma exchange group, the level of PT and serum proteins decreased significantly and PTa increased significantly after the treatment(p<0.05 or 0.01). There were not any significant differences of these changes between two groups(p>0.1 or 0.25). The side effects were light and limited in the all cases. Conclusion: Both artificial liver are effective in treatment of hepatic failure, and the support effects of middle artificial liver is similar to that of physical artificial liver.
Keywords:hepatic failure   artificial liver   liver support