首页 | 本学科首页   官方微博 | 高级检索  
     

实时阈值手动触发技术在多排螺旋CT下肢动脉成像中的临床应用价值研究
引用本文:黄庆宁. 实时阈值手动触发技术在多排螺旋CT下肢动脉成像中的临床应用价值研究[J]. 中国CT和MRI杂志, 2017, 0(10): 139-141. DOI: 10.3969/j.issn.1672-5131.2017.10.043
作者姓名:黄庆宁
作者单位:广西贺州广济医院放射科 广西 贺州 542899
摘    要:目的研究实时阈值手动触发技术在多排螺旋CT下肢动脉成像中的临床效果及应用价值,为临床提供依据。方法选取2015年1月-2016年5月医院诊治的疑似下肢动脉病变患者70例,根据检测方法不同将患者分为对照组35例和观察组35例。对照组采用手动触发,待时间密度曲线图到峰值稳定后手动启动扫描,观察组采用实时阈值手动触发技术待阈值达到150Hu后延迟6s启动扫描,比较两组图像质量。结果观察组患者诊断时平均延迟时间,显著短于对照组(P0.05);两组患者主-髂部血管、骨-腘部血管动脉边缘及动脉分支图像质量评分差异无统计学意义(P0.05);观察组膝下部血管、足部血管动脉边缘及动脉分支图像质量评分,显著高于对照组(P0.05);两组患者髂总动脉、股腘动脉、胫前动脉及足背动脉静脉干扰评分差异无统计学意义(P0.05)。结论疑似下肢动脉病变患者采用实时阈值手动触发技术诊断效果理想,能延迟扫描时间,提高下肢动脉图像,值得推广应用。

关 键 词:实时阈值手动触发技术  多排螺旋CT  下肢动脉成像  临床效果  应用价值

Real-time Threshold Value Manually Trigger Value of Clinical Application of Technology in a Multi-slice Spiral CT Imaging of Lower Limb Arteries
Abstract:Objective To study the real-time triggering threshold value manually clinical effect and value of multi-slice spiral CT in lower extremity arteries imaging for clinical basis.Methods January 2015-May 2016 suspected of 70 cases of lower extremity arterial disease patients to hospital for treatment, the patients were divided into different control group of 35 cases and 35 cases of observation group according to the detection method. The control group was triggered manually, until the time density curve to a peak steady manually initiate a scan, real-time observation group threshold value manually triggering threshold to be reached 150Hu delay 6s start scanning, image quality between the two groups.Results The observed cohort, average delay time was significantly shorter than the control group (P<0.05), two groups were the main-iliac vessels, bone-popliteal artery and arteries edge image quality score difference was not statistically significant (P>0.05), the observation group blood vessels below the knee, foot and edge arteries artery image quality score was significantly higher (P<0.05), two groups were common iliac artery, femoral popliteal artery, anterior tibial artery and foot dorsal artery vein interference score was no significant difference (P>0.05).Conclusion Patients with suspected lower extremity arterial disease by real-time triggering threshold value manually over the diagnosis can be delayed scan time and improve the image of lower extremity arteries, should be widely applied.
Keywords:Real-time Manual  Triggering Threshold  Multi-slice Spiral CT  Lower Extremity Arteries Imaging  Clinical Effect  Value
本文献已被 CNKI 万方数据 等数据库收录!