首页 | 本学科首页   官方微博 | 高级检索  
检索        


Comparison of independent double readings and computer-aided diagnosis (CAD) for the diagnosis of breast calcifications
Authors:Jiang Yulei  Nishikawa Robert M  Schmidt Robert A  Metz Charles E
Institution:Department of Radiology, The University of Chicago, 5841 South Maryland Avenue, Chicago, IL 60637.
Abstract:RATIONALE AND OBJECTIVES: The aim of the study is to compare independent double readings by radiologists and computer-aided diagnosis (CAD) in diagnostic interpretation of mammographic calcifications. MATERIALS AND METHODS: Ten radiologists independently interpreted 104 mammograms containing clustered microcalcifications. Forty-six of these were malignant and 58 were benign at biopsy. Radiologists read the images with and without a computer aid by using a counterbalanced study design. Sensitivity and specificity were calculated from observer biopsy recommendations, and receiver operating characteristic (ROC) curves were computed from their diagnostic confidence ratings. Unaided double-reading sensitivity and specificity values were derived post hoc by using three different objective rules and an additional rule of simulated-optimal double reading that assumed that consultations for resolving two radiologists' different independent diagnoses always produce the correct clinical recommendation. ROC curves of unaided double readings were obtained according to the literature. RESULTS: Single reading without computer aid yielded 74% sensitivity and 32% specificity, whereas CAD reading yielded 87% sensitivity and 42% specificity and appeared on a higher ROC curve (P < .0001). Three methods of formulating independent double readings generated sensitivities between 59% and 89%, specificities between 50% and 13%, and operating points that moved essentially along the average unaided single-reading ROC curve. ROC curves of unaided independent double readings showed small, statistically insignificant improvement over those of unaided single readings. Results of the simulated-optimal double reading were similar to CAD: 89% sensitivity and 50% specificity. CONCLUSION: Independent double readings of mammographic calcifications may not improve diagnostic performance. CAD reading improves diagnostic performance to an extent approaching the maximum possible performance.
Keywords:Diagnostic radiology  observer performance  receiver operating characteristic (ROC) curve  breast radiography  breast neoplasm  diagnosis  breast neoplasm  calcification  computer  diagnostic aid  
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号