氧化锌晶须填料对义齿基托树脂力学性能的影响 |
| |
引用本文: | 张潇雯,乔萍丽,吴艳芬,吴凤鸣.氧化锌晶须填料对义齿基托树脂力学性能的影响[J].中国医学文摘:口腔医学,2013(3):130-133. |
| |
作者姓名: | 张潇雯 乔萍丽 吴艳芬 吴凤鸣 |
| |
作者单位: | [1]南京医科大学口腔医学研究所,江苏南京210029 [2]南京医科大学附属口腔医院修复科,江苏南京210029 [3]南京医科大学附属口腔医院综合科,江苏南京210029 [4]同济大学附属口腔医院,上海200072 |
| |
基金项目: | 江苏高校优势学科建设工程资助项目(2011-137) |
| |
摘 要: | 目的:研究添加氧化锌晶须对基托树脂力学性能的影响。方法:将氧化锌晶须按不同的质量百分比加人基托粉中,分为空白对照组、1%、3%、5%、7%等5组。根据ISO标准测试各组的力学性能,并对试样断面进行扫描电镜观察。结果:随着氧化锌晶须用量的增加,复合材料的弯曲强度、弯曲弹性模量、显微维氏硬度呈先升后降的趋势。当氧化锌晶须用量为5%时,以上指标测得值最高,分别为(109.00±2.70)MPa、(3645.30±198.68)MPa、(20.57±0.85)kg/mm^2,树脂基托较对照组弯曲强度提高18.29%、弯曲弹性模量提高16.07%、显微维氏硬度提高29.94%。结论:氧化锌晶须填料显著增强了基托树脂的力学性能。
|
关 键 词: | 氧化锌晶须 基托树脂 弯曲强度 显微硬度 弯曲弹性模量 |
Effect of zinc oxide whiskers on mechanical properties of denture base |
| |
Authors: | ZHANG Xiaowen QIAO Pingli WU Yanfeng WU Fengming |
| |
Institution: | 1. Institute of Stomatology , School of Stomatology, Nanjing Medical University, Nanjing 210029, China ; 2. Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical Uni- versity, Nanjing 210029, China ; 3. Department of General Dentistry, Affiliated Hospital of Stomatology, Nanfing Medical University, Nan- ring 210029, China ;4. Affiliated Hospital of Stomatology, Tongji University, Shanghai 200072, China) |
| |
Abstract: | Objective: This study intended to investigate the mechanical properties of polymethyl methyacrylate denture base into which zinc oxide whiskers was added. Methods:We conducted the study on five groups divided according to zinc oxide whiskers con- tent which was added to the denture base including control at the rate of 1% , 3% , 5% and 7%. ISO standard was applied in mechan- ical tests, and the fractured surfaces of specimens were examined under SEM. Results :Flexural strength, flexural modulus and micro- hardness of composite material increased with the increasing content of zinc oxide whiskers in a limited range. The results showed that the flexural strength, flexural modulus and hardness of composite material rising up to (109. 00 ± 2.70) MPa, (3645.30 ± 198.68 ) MPa, (20. 57 ± 0.85 ) kg/mm2 , when the amount of zinc oxide whiskers in the base made up 5% of the total. And the flexural strength of the composites was enhanced by 18.29% , flexural modulus by 16.07% ,and hardness by 29.9% compared with that of the control group. Conclusions:Zinc oxide whiskers filler significantly enhanced mechanical properties of denture base. |
| |
Keywords: | Zinc oxide whisker Base resin Flexural strength M icrohardness Flexural modulus |