首页 | 本学科首页   官方微博 | 高级检索  
     


Optimized preoperative planning of calcaneal fractures using spiral computed tomography
Authors:M. Freund  M. Thomsen  B. Hohendorf  W. Zenker  M. Heller
Affiliation:(1) Department of Radiology, Medical School, University of Kiel, Arnold-Heller-Strasse 9, D-24105 Kiel, Germany, DE;(2) Department of Traumatology, Medical School, University of Kiel, Arnold-Heller-Strasse 9, D-24105 Kiel, Germany, DE;(3) Department of Orthopedic Surgery, Medical School, University of Heidelberg, D-69120 Heidelberg, Germany, DE
Abstract:The aim of this study was the evaluation of spiral-CT examinations in preoperative planning of calcaneal fractures supported by 3D reconstructions after electronic disarticulation. We examined 45 patients with 47 calcaneal fractures with diagnostic spiral-CT examinations in a prospective study. In addition to the conventional axial slices and sagittal reconstructions, 3D reconstructions prior to and after electronic disarticulation were performed and rated by orthopaedic surgeons and radiologists. The following diagnostic criteria were rated: involvement of articular facets, number of fragments and hindfoot deformities. Axial slices were considered to be the gold standard, because not all patients underwent surgical treatment. Axial slices showed involvement of 90 articular facets (100 %). Three-dimensional reformations after electronic disarticulation depicted 82 fractures (82 of 90, 91 %), sagittal reconstructions 63 fractures (63 of 90, 70 %). Three-dimensional reconstructions without electronic disarticulation showed five fractures (5 of 90, 5.5 %). The number of fragments was demonstrated best on sagittal reconstructions (two, three or four fragments); five fragments were diagnosed best on axial slices, and 3D reconstruction without electronic disarticulation showed only a very small number of fragments, due to overlaying bones. Hindfoot deformities (lateralisation, varus deformation, shortening) were demonstrated best on axial slices, except in terms of showing height reduction, which was demonstrated better on sagittal and 3D reconstructions. Three-dimensional reconstructions after electronic disarticulation support a clear understanding of the 3D position of the fragments and of their displacement in comparison with 3D reconstruction without electronic disarticulation, which is essential for an effective surgical reduction. Due to the potential manipulation of surface-oriented 3D reconstructions, regardless of whether electronic disarticulation is used, this imaging technique should not be considered in an isolated framework. Three-dimensional images without electronic disarticulation are superfluous in any case. Received: 1 April 1998; Revision received: 2 July 1998; Accepted: 24 September 1998
Keywords:: Spiral CT  Calcaneal fracture  Preoperative planning  3D reconstruction
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号