首页 | 本学科首页   官方微博 | 高级检索  
     


Aortic valve replacement with on-pump beating heart technique
Authors:Cicekcioglu Ferit  Tutun Ufuk  Babaroglu Seyhan  Aksoyek Aysen  Parlar Ali Ihsan  Mungan Ufuk  Tosya Alper  Tuncel Cagatay  Demirtas Ertan  Katircioglu Salih Fehmi
Affiliation:Department of Cardiovascular Surgery, Turkiye Yuksek Ihtisas Hospital, Ankara, Turkey.
Abstract:BACKGROUND: The aim of this study was to assess the efficacy and applicability of on-pump beating heart aortic valve replacement with retrograde coronary sinus (CS) warm blood perfusion. METHODS: The prospective study included 14 consecutive patients who underwent aortic valve replacement with mechanical prosthesis using retrograde CS perfusion. The operative variables and early outcome of this procedure are presented. RESULTS: Retrograde CS perfusion and venting the heart from the pulmonary vein provided good visualization of the operative field and performance of the operations without any difficulty. Partial oxygen pressures of CS perfusion blood and the returning blood from the coronary ostia were 288.5 +/- 34.4 and 39.6 +/- 4.6 mmHg, respectively. Postoperative peak creatine kinase-MB and troponin T values were mean 77.0 +/- 63.6 IU/L and mean 0.8 +/- 0.7 ng/mL, respectively. No mortality or major complication was observed and all the patients were discharged from the hospital in good condition. CONCLUSIONS: On-pump beating heart aortic valve replacement with retrograde CS warm blood perfusion is a good surgical option, and has the advantage of maintaining physiologic condition of the heart throughout the procedure.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号