首页 | 本学科首页   官方微博 | 高级检索  
检索        

反相高效液相色谱法测定心脑康胶囊中丹参酮ⅡA含量
引用本文:刘艳.反相高效液相色谱法测定心脑康胶囊中丹参酮ⅡA含量[J].中国药业,2008,17(12):46-47.
作者姓名:刘艳
作者单位:湖南省常德市药品检验所,湖南常德415101
摘    要:目的用反相高效液相色谱(RP-HPLC)法测定心脑康胶囊的丹参酮ⅡA含量。方法色谱柱Hypersil BDS C18柱(200mm×4.6mm,5μm),以甲醇-水(80:20)为流动相,检测波长为269nm,流动相流速为1.0mL/min,柱温为25℃。结果丹参酮ⅡA进样量线性范围为0.02-0.10μg(r=0.9990),平均加样回收率为98、55%,RSD=1.26%(n=6)。结论RP-HPLC法具有简便、灵敏、准确、重现性好等优点,适合于心脑康胶囊中丹参酮ⅡA的含量测定。

关 键 词:心脑康胶囊  丹参酮ⅡA  反相高效液相色谱法  含量测定

Determination of Tanshinone ⅡA in Xinnaokang Capsule by RP-HPLC
Liu Yan.Determination of Tanshinone ⅡA in Xinnaokang Capsule by RP-HPLC[J].China Pharmaceuticals,2008,17(12):46-47.
Authors:Liu Yan
Institution:Liu Yan (Changde lnstitue for Drug Control, Changde, Hunan, China 415101)
Abstract:Objectlve To establish a RP-HPLC method for the quantitative determination of Tanshinone ⅡA in Xinnaokang Capsule. Methods Reversed phase high performance liquid chromatography(RP-HPLC) was used with Hypersil BDS C18 (200 mm×4.6 mm,5 μm) column as the chromato graphic column. The mobile phase was mathanol water (80:20). The detecting wavelength was 269 nm, the flow rate was 1.0 mL/min, the column temperature was 25℃. The external standard method was employed. Results The calibration curves were linear within the range of 0.02-0.10μg (r=0.999 0) for tanshinone ⅡA. The average recovery rate was 98.55% with RSD=1. 26% (n =6). Conclusion The method is simple,accurate,highly sensitive and reproducible It can be used for quantitative determination of the tanshinone ⅡA in Xinnaokang Capsule.
Keywords:Xinnaokang Capsule  tanshinone ⅡA  RP - HPLC  content determination
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏