首页 | 本学科首页   官方微博 | 高级检索  
检索        


Development of sutureless vascular connecting system for easy implantation of small-caliber artificial grafts
Authors:Osamu Sakai  Yasuhide Nakayama  Yasushi Nemoto  Yoshihiro Okamoto  Taiji Watanabe  Keiichi Kanda  Hitoshi Yaku
Institution:(1) Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, Kyoto, Japan;(2) Department of Bioengineering, Advanced Medical Engineering Center, National Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka 565-8565, Japan;(3) Chemical Products Division, Bridgestone Corporation, Tokyo, Japan
Abstract:A novel sutureless vascular connecting system, an assembly with a delivery rod, an introducing sheath, and a connecting device, was developed for easy implantation of small-caliber vascular grafts less than 2 mm in internal diameter. A microporous stainless tube (length 2 mm, external diameter 1.6 mm, wall thickness 65 µm, pore diameter 400 µm, pore-to-pore distance 500 µm) was designed to serve as a connecting device. The feasibility of the system was tested using two types of preliminary animal experiments. One animal model consisted of graft implantation into the rat abdominal aorta (1.5 mm in diameter). The connecting device was inserted into the proximal and distal ends of the aorta through the introducing sheath by pushing the delivery rod with the connecting device placed over it. Subsequently, the aortic segments were inserted into both ends of model grafts made of segmented polyurethane (1.8 mm in internal diameter) and were fixed with banding silk threads from the exterior. The procedure was completed within 20 min without requiring specialized microsurgery techniques. Blood leakage and obstruction did not occur. The second model consisted of an end-to-end anastomosis between rabbit common carotid arteries (2 mm in diameter), which was performed within several minutes of blood flow interruption. Scanning electron microscopy demonstrated that the luminal surface of the device was fully covered with endothelial cells (ECs) after 1 week as a result of transluminal ingrowth of native ECs through the micropores in the device. This endothelialization may prevent early thrombus-induced occlusion. This simple and “easy-to-learn” technique will promote the development of small-caliber arterial grafts, and furthermore, it may have potential for clinical application.
Keywords:Sutureless vascular connecting system  Graft implantation  Small-caliber vascular graft  Microporous tube  Anastomosis
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号