首页 | 本学科首页   官方微博 | 高级检索  
检索        


Localized rest and stress human cardiac creatine kinase reaction kinetics at 3 T
Authors:William T Clarke  Mark A Peterzan  Jennifer J Rayner  Rana A Sayeed  Mario Petrou  George Krasopoulos  Hannah A Lake  Betty Raman  William D Watson  Pete Cox  Moritz J Hundertmark  Andrew P Apps  Craig A Lygate  Stefan Neubauer  Oliver J Rider  Christopher T Rodgers
Abstract:Changes in the kinetics of the creatine kinase (CK) shuttle are sensitive markers of cardiac energetics but are typically measured at rest and in the prone position. This study aims to measure CK kinetics during pharmacological stress at 3 T, with measurement in the supine position. A shorter “stressed saturation transfer” (StreST) extension to the triple repetition time saturation transfer (TRiST) method is proposed. We assess scanning in a supine position and validate the MR measurement against biopsy assay of CK activity. We report normal ranges of stress CK forward rate (kfCK) for healthy volunteers and obese patients. TRiST measures kfCK in 40 min at 3 T. StreST extends the previously developed TRiST to also make a further kfCK measurement during <20 min of dobutamine stress. We test our TRiST implementation in skeletal muscle and myocardium in both prone and supine positions. We evaluate StreST in the myocardium of six healthy volunteers and 34 obese subjects. We validated MR‐measured kfCK against biopsy assays of CK activity. TRiST kfCK values matched literature values in skeletal muscle (kfCK = 0.25 ± 0.03 s?1 vs 0.27 ± 0.03 s?1) and myocardium when measured in the prone position (0.32 ± 0.15 s?1), but a significant difference was found for TRiST kfCK measured supine (0.24 ± 0.12 s?1). This difference was because of different respiratory‐ and cardiac‐motion‐induced B0 changes in the two positions. Using supine TRiST, cardiac kfCK values for normal‐weight subjects were 0.15 ± 0.09 s?1 at rest and 0.17 ± 0.15 s?1 during stress. For obese subjects, kfCK was 0.16 ± 0.07 s?1 at rest and 0.17 ± 0.10 s?1 during stress. Rest myocardial kfCK and CK activity from LV biopsies of the same subjects correlated (R = 0.43, p = 0.03). We present an independent implementation of TRiST on the Siemens platform using a commercially available coil. Our extended StreST protocol enables cardiac kfCK to be measured during dobutamine‐induced stress in the supine position.
Keywords:31P magnetic resonance spectroscopy  cardiac  creatine kinase  energy metabolism  phosphorus  saturation transfer  StreST  TRiST
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号